Published May 2005 | Journal article | Version v1 | https://doi.org/10.1097/01.rct.0000160425.63884.5b

Registration and Fusion of CT and MRI of the Temporal Bone

Additional details

Dates

Issued
May 2005

References

  1. Hill, D. L., Hawkes, D. J., Gleeson, M. J., Cox, T. C., Strong, A. J., Wong, W. L., Ruff, C. F., Kitchen, N. D., Thomas, D. G., & Sofat, A. (1994). Accurate frameless registration of MR and CT images of the head: applications in planning surgery and radiation therapy. Radiology, 191(2), 447–454. https://doi.org/10.1148/radiology.191.2.8153319
  2. Maintz, J. B. A., & Viergever, M. A. (1998). A survey of medical image registration. Medical Image Analysis, 2(1), 1–36. https://doi.org/10.1016/s1361-8415(01)80026-8
  3. Schmalbrock, P. (2000). Comparison of three-dimensional fast spin echo and gradient echo sequences for high-resolution temporal bone imaging. Journal of Magnetic Resonance Imaging, 12(6), 814–825. https://doi.org/10.1002/1522-2586(200012)12:6%3C814::aid-jmri4%3E3.0.co;2-l
  4. Gering, D. T., Nabavi, A., Kikinis, R., Hata, N., O'Donnell, L. J., Grimson, W. E. L., Jolesz, F. A., Black, P. M., & Wells, W. M. (2001). An integrated visualization system for surgical planning and guidance using image fusion and an open MR. Journal of Magnetic Resonance Imaging, 13(6), 967–975. https://doi.org/10.1002/jmri.1139
  5. Fitzpatrick, J. M., Hill, D. L. G., Shyr, Y., West, J., Studholme, C., & Maurer, C. R. (1998). Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain. IEEE Transactions on Medical Imaging, 17(4), 571–585. https://doi.org/10.1109/42.730402
  6. Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001). Medical image registration. Physics in Medicine and Biology, 46(3), R1–R45. https://doi.org/10.1088/0031-9155/46/3/201
  7. Muren, C. (1986). The Internal Acoustic Meatus. Acta Radiologica. Diagnosis, 27(5), 505–512. https://doi.org/10.1177/028418518602700504
  8. Gulya, A. J., & Steenerson, R. L. (1996). The Scala Vestibuli for Cochlear Implantation: An Anatomic Study. Archives of Otolaryngology - Head and Neck Surgery, 122(2), 130–132. https://doi.org/10.1001/archotol.1996.01890140020005
  9. Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000). Voxel similarity measures for 3-D serial MR brain image registration. IEEE Transactions on Medical Imaging, 19(2), 94–102. https://doi.org/10.1109/42.836369
  10. Mutic, S., Dempsey, J. F., Bosch, W. R., Low, D. A., Drzymala, R. E., Chao, K. S. C., Goddu, S. M., Cutler, P. D., & Purdy, J. A. (2001). Multimodality image registration quality assurance for conformal three-dimensional treatment planning. International Journal of Radiation Oncology*Biology*Physics, 51(1), 255–260. https://doi.org/10.1016/s0360-3016(01)01659-5
  11. Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996). Multi-modal volume registration by maximization of mutual information. Medical Image Analysis, 1(1), 35–51. https://doi.org/10.1016/s1361-8415(01)80004-9
  12. West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., Maes, F., Suetens, P., Vandermeulen, D., van den Elsen, P. A., Napel, S., Sumanaweera, T. S., Harkness, B., Hemler, P. F., Hill, D. L. G., … Woods, R. P. (1997). Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques. Journal of Computer Assisted Tomography, 21(4), 554–568. https://doi.org/10.1097/00004728-199707000-00007
  13. Rodriguez, J. R., Castillo, J., Leira, R., Pardo, J., Lema, M., & Noya, M. (1991). Bone anomalies in myotonic dystrophy. Acta Neurologica Scandinavica, 83(6), 360–363. https://doi.org/10.1111/j.1600-0404.1991.tb03963.x

Citations

  1. https://doi.org/10.70675/339d2144z7a46z4356za134z85b00616c527
  2. Wang, J., Couvreur, F., Farrell, J. D., Ghedia, R., Shoman, N., Morris, D. P., & Adamson, R. B. A. (2025). Fusion of Middle Ear Optical Coherence Tomography and Computed Tomography. JAMA Otolaryngology–Head & Neck Surgery, 151(5), 476. https://doi.org/10.1001/jamaoto.2025.0043
  3. Gerb, J., Kirsch, V., Kierig, E., Brandt, T., Dieterich, M., & Boegle, R. (2025). Optimizing spatial normalization of multisubject inner ear MRI: comparison of different geometry-preserving co-registration approaches. Scientific Reports, 15(1). https://doi.org/10.1038/s41598-025-90842-2
  4. You, S.-H., Cho, Y., Kim, B., Kim, J., Im, G. J., Park, E., Kim, I., Kim, K. M., & Kim, B. K. (2024). Synthetic temporal bone CT generation from UTE-MRI using a cycleGAN-based deep learning model: advancing beyond CT-MR imaging fusion. European Radiology, 35(1), 38–48. https://doi.org/10.1007/s00330-024-10967-2
  5. Wang, J., Couvreur, F., Farrell, J. D., Ghedia, R., Shoman, N., Morris, D. P., & Adamson, R. B. A. (2024). Fusion of middle ear optical coherence tomography and computed tomography in three ears [Preprint]. In medRxiv. openRxiv. https://doi.org/10.1101/2024.09.23.24314125
  6. Singh, S., Zhou, Y., Farris, A. L., Whitehead, E. C., Nyberg, E. L., O'Sullivan, A. N., Zhang, N. Y., Rindone, A. N., Achebe, C. C., Zbijewski, W., Grundy, W., Garlick, D., Jackson, N. D., Kraitchman, D., Izzi, J. M., Lopez, J., Grant, M. P., & Grayson, W. L. (2023). Geometric Mismatch Promotes Anatomic Repair in Periorbital Bony Defects in Skeletally Mature Yucatan Minipigs. Advanced Healthcare Materials, 12(29). https://doi.org/10.1002/adhm.202301944
  7. https://doi.org/10.1371/journal.pone.0264449
  8. https://doi.org/10.1186/s40463-020-00411-y
  9. https://doi.org/10.1371/journal.pone.0218268
  10. Kayyali, M. N., Wright, A. C., Ramsey, A. J., Brant, J. A., Stein, J. M., O'Malley, B. W., & Li, D. (2018). Challenges and opportunities in developing targeted molecular imaging to determine inner ear defects of sensorineural hearing loss. Nanomedicine: Nanotechnology, Biology and Medicine, 14(2), 397–404. https://doi.org/10.1016/j.nano.2017.10.004
  11. Dragovic, A. S., Stringer, A. K., Campbell, L., Shaul, C., O’Leary, S. J., & Briggs, R. J. (2018). Co-registration of cone beam CT and preoperative MRI for improved accuracy of electrode localization following cochlear implantation. Cochlear Implants International, 19(3), 147–152. https://doi.org/10.1080/14670100.2017.1419548
  12. https://doi.org/10.1201/b10720-17
  13. https://doi.org/10.3389/fsurg.2016.00002
  14. https://doi.org/10.1201/b18983-17
  15. Arora, A., Swords, C., Khemani, S., Awad, Z., Darzi, A., Singh, A., & Tolley, N. (2014). Virtual reality case-specific rehearsal in temporal bone surgery: A preliminary evaluation. International Journal of Surgery, 12(2), 141–145. https://doi.org/10.1016/j.ijsu.2013.11.019
  16. Noorda, Y. H., Bartels, L. W., Huisman, M., Nijenhuis, R. J., van den Bosch, M. A., & Pluim, J. P. (2014). Registration of CT to pre-treatment MRI for planning of MR-HIFU ablation treatment of painful bone metastases. Physics in Medicine and Biology, 59(15), 4167–4179. https://doi.org/10.1088/0031-9155/59/15/4167
  17. https://doi.org/10.1115/1.4025692
  18. https://doi.org/10.1371/journal.pone.0065672
  19. https://doi.org/10.4028/www.scientific.net/amm.145.93
  20. Horii, A., Kitahara, T., Osaki, Y., Imai, T., Fukuda, K., Sakagami, M., & Inohara, H. (2010). Intractable Benign Paroxysmal Positioning Vertigo: Long-Term Follow-Up and Inner Ear Abnormality Detected by Three-Dimensional Magnetic Resonance Imaging. Otology & Neurotology, 31(2), 250–255. https://doi.org/10.1097/mao.0b013e3181cabd77
  21. Sobrinho, F. P., Lazarini, P. R., Yoo, H. J., Júnior, L. de A., & Meira, A. de S. (2009). A method for measuring the length of the coclea through magnetic resonance imaging. Brazilian Journal of Otorhinolaryngology, 75(2), 261–267. https://doi.org/10.1016/s1808-8694(15)30788-6
  22. https://doi.org/10.1590/s0034-72992009000200017
  23. Ferrarini, L., Verbist, B. M., Olofsen, H., Vanpoucke, F., Frijns, J. H. M., Reiber, J. H. C., & Admiraal-Behloul, F. (2008). Autonomous virtual mobile robot for three-dimensional medical image exploration: Application to micro-CT cochlear images. Artificial Intelligence in Medicine, 43(1), 1–15. https://doi.org/10.1016/j.artmed.2008.03.004
  24. https://doi.org/10.1177/197140090802100316
  25. Mehta, R. P., Cueva, R. A., Dale Brown, J., Fliss, D. M., Gil, Z., Kassam, A. B., Rassekh, C. H., Schlosser, R. J., Snyderman, C. H., & Har‐El, G. (2006). What's New in Skull Base Medicine and Surgery? Skull Base Committee Report. Otolaryngology–Head and Neck Surgery, 135(4), 620–630. https://doi.org/10.1016/j.otohns.2006.04.018