Published August 23, 2016 | Journal article | Version v1 | https://doi.org/10.4081/audiores.2016.154

Transient Noise Reduction in Cochlear Implant Users: A Multi-Band Approach

Description

A previously-tested transient noise reduction (TNR) algorithm for cochlear implant (CI) users was modified to detect and attenuate transients independently across multiple frequency-bands. Since speech and transient noise are often spectrally distinct, we hypothesized that benefits in speech intelligibility can be achieved over the earlier single- band design. Fifteen experienced CI users (49 to 72 years) were tested unilaterally using pre-processed stimuli delivered directly to a speech processor. Speech intelligibility in transient and soft stationary noise, subjective sound quality and the recognition of warning signals was investigated in three processing conditions: no TNR (TNRoff), single- band TNR (TNRsgl) and multi-band TNR (TNRmult). Notably, TNRmult improved speech reception thresholds (SRTs) in cafeteria noise and office noise by up to 3 dB over both TNRoff and TNRsgl, and yielded higher comfort and clarity ratings in cafeteria noise. Our results indicate that multi-band transient noise reduction may be advantageous compared to a single-band approach, and reveal a substantial overall potential for TNR to improve speech perception and listening comfort in CI users.

Additional details

Dates

Issued
August 23, 2016

References

  1. Buechner, A., Brendel, M., Saalfeld, H., Litvak, L., Frohne-Buechner, C., & Lenarz, T. (2010). Results of a Pilot Study With a Signal Enhancement Algorithm for HiRes 120 Cochlear Implant Users. Otology & Neurotology, 31(9), 1386–1390. https://doi.org/10.1097/mao.0b013e3181f1cdc6
  2. Henderson, D., & Hamernik, R. P. (1986). Impulse noise: Critical review. The Journal of the Acoustical Society of America, 80(2), 569–584. https://doi.org/10.1121/1.394052
  3. An assessment of everyday noises and their annoyance
  4. Korhonen, P., Kuk, F., Lau, C., Keenan, D., Schumacher, J., & Nielsen, J. (2013). Effects of a Transient Noise Reduction Algorithm on Speech Understanding, Subjective Preference, and Preferred Gain. Journal of the American Academy of Audiology, 24(9), 845–858. https://doi.org/10.3766/jaaa.24.9.8
  5. Buechner, A., Dyballa, K.-H., Hehrmann, P., Fredelake, S., Lenarz, T., & Wanunu, M. (2014). Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions. PLoS ONE, 9(4), e95542. https://doi.org/10.1371/journal.pone.0095542
  6. Transient impulse control for hearing aids
  7. Chalupper, J., & Powers, T. A. (2007). New algorithm is designed to take the annoyance out of transient noise. The Hearing Journal, 60(7), 42. https://doi.org/10.1097/01.hj.0000281790.84712.02
  8. DiGiovanni, J. J., Davlin, E. A., & Nagaraj, N. K. (2011). Effects of Transient Noise Reduction Algorithms on Speech Intelligibility and Ratings of Hearing Aid Users. American Journal of Audiology, 20(2), 140–150. https://doi.org/10.1044/1059-0889(2011/10-0007)
  9. Keidser, G., O'Brien, A., Latzel, M., & Convery, E. (2007). Evaluation of a noise-reduction algorithm that targets non-speech transient sounds. The Hearing Journal, 60(2), 29. https://doi.org/10.1097/01.hj.0000285643.45157.35
  10. Liu, H., Zhang, H., Bentler, R. A., Han, D., & Zhang, L. (2012). Evaluation of a Transient Noise Reduction Strategy for Hearing Aids. Journal of the American Academy of Audiology, 23(8), 606–615. https://doi.org/10.3766/jaaa.23.8.4
  11. Dyballa, K.-H., Hehrmann, P., Hamacher, V., Nogueira, W., Lenarz, T., & Büchner, A. (2015). Evaluation of A Transient Noise Reduction Algorithm in Cochlear Implant Users. Audiology Research, 5(2), 116. https://doi.org/10.4081/audiores.2015.116
  12. Holube, I., Fredelake, S., Vlaming, M., & Kollmeier, B. (2010). Development and analysis of an International Speech Test Signal (ISTS). International Journal of Audiology, 49(12), 891–903. https://doi.org/10.3109/14992027.2010.506889
  13. Peterson, G. E., & Barney, H. L. (1952). Control Methods Used in a Study of the Vowels. The Journal of the Acoustical Society of America, 24(2), 175–184. https://doi.org/10.1121/1.1906875
  14. Transient interference suppression in speech signals based on the OM-LSA algorithm
  15. Brendel, M., Buechner, A., Krueger, B., Frohne-Buechner, C., & Lenarz, T. (2008). Evaluation of the Harmony Soundprocessor in Combination With the Speech Coding Strategy HiRes 120. Otology & Neurotology, 29(2), 199–202. https://doi.org/10.1097/mao.0b013e31816335c6
  16. Boyle, P. J., Büchner, A., Stone, M. A., Lenarz, T., & Moore, B. C. J. (2009). Comparison of dual-time-constant and fast-acting automatic gain control (AGC) systems in cochlear implants. International Journal of Audiology, 48(4), 211–221. https://doi.org/10.1080/14992020802581982
  17. Kollmeier, B., & Wesselkamp, M. (1997). Development and evaluation of a German sentence test for objective and subjective speech intelligibility assessment. The Journal of the Acoustical Society of America, 102(4), 2412–2421. https://doi.org/10.1121/1.419624
  18. The HSM sentence test as a tool for evaluating the speech understanding in noise of cochlear implant users
  19. Practical nonparametric statistics
  20. Is the hearing instrument to blame when things get really noisy