Vibration response imaging (VRI) in lung transplant recipients
Description
Background: In the first 6 months following lung transplantation, the most frequently occurring complications are infection, acute rejection and anastomotic dysfunction. The utility of vibration response imaging (VRI) lung images in assisting with the detection of these complications was evaluated. Objectives: The study aimed to evaluate if VRI is a good, non-invasive method of detecting clinical problems in lung transplant (LTx) recipients during early follow-up. Methods: Between 06/2006 and 03/2007 all LTx patients who received transplants during the preceding 6 months at the Hannover Medical School received baseline VRI at enrolment with subsequent reassessment in combination with standard follow-up at 1, 3 and 6 months thereafter. The resulting images were analysed by two blinded reviewers. Results: Fifty-five lung transplant recipients were enrolled in the study, with 49 patients successfully completing follow-up. Device operability and patient participation occurred without significant problems. High numbers of abnormal scans were detected. According to the clinical diagnosis, 29 patients (59.2 %) were stable at all four visits. Twenty clinical problems occurred (e.g., infections, rejections, obstructions, unknown deterioration). Agreement with clinical interpretation of rejections and infections was poor. Central airway obstruction (CAO) was detected in 80% by both reviewers. Accuracy in detecting obstructions was 89%; positive predicted value and negative predicted value were 80% and 90%, respectively. Conclusion: The VRI system is a non-invasive easy-to-use method with technical success and good image quality. The high number of abnormal scans makes interpretation following LTx difficult. VRI was unable to detect deterioration in graft function with the exception of ventilation disorders like central airway complications.
Additional details
Identifiers
- OpenAlex
- W2168782008
- PMID
- 20042451
- URL
- https://journals.sagepub.com/doi/10.1177/1753465809356293
Dates
- Issued
-
December 30, 2009
References
- Anantham, D., Herth, F. J. F., Majid, A., Michaud, G., & Ernst, A. (2008). Vibration Response Imaging in the Detection of Pleural Effusions: A Feasibility Study. Respiration, 77(2), 166–172. https://doi.org/10.1159/000168784
- Becker, H. D., Slawik, M., Miyazawa, T., & Gat, M. (2008). Vibration Response Imaging as a New Tool for Interventional-Bronchoscopy Outcome Assessment: A Prospective Pilot Study. Respiration, 77(2), 179–194. https://doi.org/10.1159/000182972
- Blanco, M., Mor, R., Fraticelli, A., Breen, D. P., & Dutau, H. (2008). Distribution of Breath Sound Images in Patients with Pneumothoraces Compared to Healthy Subjects. Respiration, 77(2), 173–178. https://doi.org/10.1159/000181166
- Chughtai, A., Cronin, P., Kelly, A. M., & Kazerooni, E. A. (2006). Lung Transplantation Imaging in the Adult. Seminars in Roentgenology, 41(1), 26–35. https://doi.org/10.1053/j.ro.2005.08.005
- Collins, J. (2002). Imaging of the Chest After Lung Transplantation. Journal of Thoracic Imaging, 17(2), 102–112. https://doi.org/10.1097/00005382-200204000-00002
- Dellinger, R. P., Parrillo, J. E., Kushnir, A., Rossi, M., & Kushnir, I. (2007). Dynamic Visualization of Lung Sounds with a Vibration Response Device: A Case Series. Respiration, 75(1), 60–72. https://doi.org/10.1159/000103558
- Dierich, M., Fuehner, T., Welte, T., Simon, A., & Gottlieb, J. (2009). Lungentransplantation: Indikationen, Langzeitergebnisse und die besondere Bedeutung der Nachsorge. Der Internist, 50(5), 561–571. https://doi.org/10.1007/s00108-008-2271-0
- Jean, S., Cinel, I., Gratz, I., Tay, C., Lotano, V., Deal, E., Parrillo, J. E., & Dellinger, R. P. (2008). Image-based monitoring of one-lung ventilation. European Journal of Anaesthesiology, 25(12), 995–1001. https://doi.org/10.1017/s0265021508004481
- Kotloff, R. M., & Ahya, V. N. (2004). Medical complications of lung transplantation. European Respiratory Journal, 23(2), 334–342. https://doi.org/10.1183/09031936.03.00043403
- Kramer, M. R., Raviv, Y., Hardoff, R., Shteinmatz, A., Amital, A., & Shitrit, D. (2007). Regional Breath Sound Distribution Analysis in Single-lung Transplant Recipients. The Journal of Heart and Lung Transplantation, 26(11), 1149–1154. https://doi.org/10.1016/j.healun.2007.07.039
- Kugler, C., Fischer, S., Gottlieb, J., Tegtbur, U., Welte, T., Goerler, H., Simon, A., Haverich, A., & Strueber, M. (2007). Symptom experience after lung transplantation: impact on quality of life and adherence. Clinical Transplantation, 21(5), 590–596. https://doi.org/10.1111/j.1399-0012.2007.00693.x
- Maher, T. M., Gat, M., Allen, D., Devaraj, A., Wells, A. U., & Geddes, D. M. (2007). Reproducibility of dynamically represented acoustic lung images from healthy individuals. Thorax, 63(6), 542–548. https://doi.org/10.1136/thx.2007.086405
- Murthy, S. C., Blackstone, E. H., Gildea, T. R., Gonzalez-Stawinski, G. V., Feng, J., Budev, M., Mason, D. P., Pettersson, G. B., & Mehta, A. C. (2007). Impact of Anastomotic Airway Complications After Lung Transplantation. The Annals of Thoracic Surgery, 84(2), 401–409.e4. https://doi.org/10.1016/j.athoracsur.2007.05.018
- Orens, J. B., Estenne, M., Arcasoy, S., Conte, J. V., Corris, P., Egan, J. J., Egan, T., Keshavjee, S., Knoop, C., Kotloff, R., Martinez, F. J., Nathan, S., Palmer, S., Patterson, A., Singer, L., Snell, G., Studer, S., Vachiery, J. L., & Glanville, A. R. (2006). International Guidelines for the Selection of Lung Transplant Candidates: 2006 Update—A Consensus Report From the Pulmonary Scientific Council of the International Society for Heart and Lung Transplantation. The Journal of Heart and Lung Transplantation, 25(7), 745–755. https://doi.org/10.1016/j.healun.2006.03.011
- Yigla, M., Gat, M., Meyer, J.-J., Friedman, P. J., Maher, T. M., & Madison, J. M. (2008). Vibration Response Imaging Technology in Healthy Subjects. American Journal of Roentgenology, 191(3), 845–852. https://doi.org/10.2214/ajr.07.3151