Published October 22, 2021 | Journal article | Version v1 | https://doi.org/10.1186/s13256-021-03095-8

Implantation of an attachment tube preserves knee extension after nonunion of Felix IV fracture: a case report

Description

Abstract Background While commonly utilized to fix tissue and muscles to megaprostheses to restore function and stability after tumor surgery, an attachment tube was used as a synthetic reconstruction of the knee joint's extension mechanism after nonunion of Felix IV C fracture. Fixation of the tibial fragment, and therefore its osteointegration, is complicated after total knee arthroplasty, causing tibial tubercle dislocation. Case presentation A 61-year-old German patient presented to our clinic with Felix IV C fracture, persistent knee pain, and reduced knee extension strength. In this special case, mobilization and reattachment of the tibial tubercle was not possible because of necrosis and underlying tibial component. Therefore, we covered the defect with cement and used an polyethylene terephthalate tube for knee extension system augmentation. Follow-up after 10 months demonstrated a good clinical result. Conclusion The management of Felix IV C fractures is complicated by the underlying prosthesis resulting in redislocation of the fragment and persistent symptoms of pain and reduced functionality. We here present a new surgical technique to treat periprosthetic fracture complicated by tibial tubercle dislocation. Good clinical and radiologic results on follow-up after 10 months indicate the use of attachment tubes as a suitable surgical technique to restore knee joint extension and to reduce knee pain after dislocated Felix IV C fracture.

Additional details

Funding

Medizinische Hochschule Hannover (MHH)

Dates

Issued
October 22, 2021

References

  1. Yoo, J. D., & Kim, N. K. (2015). Periprosthetic Fractures Following Total Knee Arthroplasty. Knee Surgery & Related Research, 27(1), 1–9. https://doi.org/10.5792/ksrr.2015.27.1.1
  2. Inacio, M. C. S., Paxton, E. W., Graves, S. E., Namba, R. S., & Nemes, S. (2017). Projected increase in total knee arthroplasty in the United States – an alternative projection model. Osteoarthritis and Cartilage, 25(11), 1797–1803. https://doi.org/10.1016/j.joca.2017.07.022
  3. Morwood, M. P., Gebhart, S. S., Zamith, N., & Mir, H. R. (2019). Outcomes of fixation for periprosthetic tibia fractures around and below total knee arthroplasty. Injury, 50(4), 978–982. https://doi.org/10.1016/j.injury.2019.03.014
  4. Felix, N. A., Stuart, M. J., & Hanssen, A. D. (1997). Periprosthetic Fractures of the Tibia Associated With Total Knee Arthroplasty. Clinical Orthopaedics and Related Research, 345, 113???124. https://doi.org/10.1097/00003086-199712000-00016
  5. Kim, H.-J., Park, K.-C., Kim, J.-W., Oh, C.-W., Kyung, H.-S., Oh, J.-K., Park, K.-H., & Yoon, S.-D. (2017). Successful outcome with minimally invasive plate osteosynthesis for periprosthetic tibial fracture after total knee arthroplasty. Orthopaedics & Traumatology: Surgery & Research, 103(2), 263–268. https://doi.org/10.1016/j.otsr.2016.10.007
  6. Thiele, K., von Roth, P., Pfitzner, T., Preininger, B., & Perka, C. (2016). Quadrizepssehneninsuffizienzen und -rupturen. Der Orthopäde, 45(5), 407–415. https://doi.org/10.1007/s00132-016-3258-5
  7. Brown, N. M., Murray, T., Sporer, S. M., Wetters, N., Berger, R. A., & Della Valle, C. J. (2015). Extensor Mechanism Allograft Reconstruction for Extensor Mechanism Failure Following Total Knee Arthroplasty. The Journal of Bone and Joint Surgery, 97(4), 279–283. https://doi.org/10.2106/jbjs.n.00759
  8. LEOPOLD, M. S. S., GREIDANUS, N., PAPROSKY, W. G., BERGER, R. A., & ROSENBERG, A. G. (1999). High Rate of Failure of Allograft Reconstruction of the Extensor Mechanism After Total Knee Arthroplasty*†. The Journal of Bone & Joint Surgery, 81(11), 1574–9. https://doi.org/10.2106/00004623-199911000-00009
  9. Cadambi, A., & Engh, G. A. (1992). Use of a semitendinosus tendon autogenous graft for rupture of the patellar ligament after total knee arthroplasty. A report of seven cases. The Journal of Bone & Joint Surgery, 74(7), 974–979. https://doi.org/10.2106/00004623-199274070-00003
  10. Browne, J. A., & Hanssen, A. D. (2011). Reconstruction of Patellar Tendon Disruption After Total Knee Arthroplasty. The Journal of Bone & Joint Surgery, 93(12), 1137–1143. https://doi.org/10.2106/jbjs.j.01036
  11. Hardes, J., Ahrens, H., Nottrott, M., Dieckmann, R., Gosheger, G., Henrichs, M.-P., & Streitbürger, A. (2012). Der Anbindungsschlauch zur Weichteilrekonstruktion nach Megaprothesenimplantation. Operative Orthopädie und Traumatologie, 24(3), 227–234. https://doi.org/10.1007/s00064-011-0080-4
  12. Gosheger, G., Hillmann, A., Lindner, N., R??dl, R., Hoffmann, C., B??rger, H., & Winkelmann, W. (2001). Soft Tissue Reconstruction of Megaprostheses Using a Trevira Tube. Clinical Orthopaedics and Related Research, 393, 264–271. https://doi.org/10.1097/00003086-200112000-00030
  13. Holzapfel, B. M., Pilge, H., Toepfer, A., Jakubietz, R. G., Gollwitzer, H., Rechl, H., von Eisenhart-Rothe, R., & Rudert, M. (2012). Proximaler Tibiaersatz und alloplastische Rekonstruktion des Streckapparats nach Resektion kniegelenksnaher Tumoren. Operative Orthopädie und Traumatologie, 24(3), 247–262. https://doi.org/10.1007/s00064-012-0187-2
  14. Wilken, F., Banke, I. J., Hauschild, M., Winkler, S., Schott, K., Rudert, M., & Eisenhart-Rothe, R. v . (2016). Tumorendoprothetik. Der Orthopäde, 45(5), 439–445. https://doi.org/10.1007/s00132-016-3255-8
  15. Gosheger, G., Gebert, C., Ahrens, H., Streitbuerger, A., Winkelmann, W., & Hardes, J. (2006). Endoprosthetic Reconstruction in 250 Patients with Sarcoma. Clinical Orthopaedics and Related Research, 450, 164–171. https://doi.org/10.1097/01.blo.0000223978.36831.39
  16. Trieb, K., Blahovec, H., Brand, G., Sabeti, M., Dominkus, M., & Kotz, R. (2004). In vivo and in vitro Cellular Ingrowthinto a New Generation of Artificial Ligaments. European Surgical Research, 36(3), 148–151. https://doi.org/10.1159/000077256