Transcutaneous electromagnetic induction heating of an intramedullary nickel–titanium shape memory implant
Authors/Creators
Additional details
Identifiers
- OpenAlex
- W2092964758
- PMID
- 25038974
- URL
- http://link.springer.com/10.1007/s00264-014-2460-5
Dates
- Issued
-
July 20, 2014
References
- Marsh, D. (1998). Concepts of Fracture Union, Delayed Union, and Nonunion. Clinical Orthopaedics and Related Research, 355S, S22–S30. https://doi.org/10.1097/00003086-199810001-00004
- Claes, L. E., Heigele, C. A., Neidlinger-Wilke, C., Kaspar, D., Seidl, W., Margevicius, K. J., & Augat, P. (1998). Effects of Mechanical Factors on the Fracture Healing Process. Clinical Orthopaedics and Related Research, 355S, S132–S147. https://doi.org/10.1097/00003086-199810001-00015
- Claes, L., Eckert‐Hübner, K., & Augat, P. (2002). The effect of mechanical stability on local vascularization and tissue differentiation in callus healing. Journal of Orthopaedic Research, 20(5), 1099–1105. https://doi.org/10.1016/s0736-0266(02)00044-x
- Niikura, T., Yang Lee, S., Sakai, Y., Nishida, K., Kuroda, R., & Kurosaka, M. (2014). Causative factors of fracture nonunion: the proportions of mechanical, biological, patient-dependent, and patient-independent factors. Journal of Orthopaedic Science, 19(1), 120–124. https://doi.org/10.1007/s00776-013-0472-4
- Lienau, J., Schell, H., Duda, G. N., Seebeck, P., Muchow, S., & Bail, H. J. (2005). Initial vascularization and tissue differentiation are influenced by fixation stability. Journal of Orthopaedic Research, 23(3), 639–645. https://doi.org/10.1016/j.orthres.2004.09.006
- Augat, P., Penzkofer, R., Nolte, A., Maier, M., Panzer, S., Oldenburg, G. v ., Pueschl, K., Simon, U., & Bühren, V. (2008). Interfragmentary Movement in Diaphyseal Tibia Fractures Fixed With Locked Intramedullary Nails. Journal of Orthopaedic Trauma, 22(1), 30–36. https://doi.org/10.1097/bot.0b013e31816073cb
- Claes, L., Blakytny, R., Göckelmann, M., Schoen, M., Ignatius, A., & Willie, B. (2008). Early dynamization by reduced fixation stiffness does not improve fracture healing in a rat femoral osteotomy model. Journal of Orthopaedic Research, 27(1), 22–27. https://doi.org/10.1002/jor.20712
- Epari, D. R., Kassi, J.-P., Schell, H., & Duda, G. N. (2007). Timely Fracture-Healing Requires Optimization of Axial Fixation Stability. The Journal of Bone & Joint Surgery, 89(7), 1575–1585. https://doi.org/10.2106/jbjs.f.00247
- Dagrenat D, Moncade N, Cordey J, Rahn BA, Kempf I, Perren SM (1988) Effects of the dynamization of static bolt nailing. in vivo experimentation. Rev Chir Orthop Reparatrice Appar Mot 74(Suppl 2):100–104
- Krettek C, Schandelmaier P, Rudolf J, Tscherne H (1994) Current status of surgical technique for unreamed nailing of tibial shaft fractures with the UTN (unreamed tibia nail). Unfallchirurg 97:575–599
- Papakostidis, C., Psyllakis, I., Vardakas, D., Grestas, A., & Giannoudis, P. V. (2011). Femoral-shaft fractures and nonunions treated with intramedullary nails: The role of dynamisation. Injury, 42(11), 1353–1361. https://doi.org/10.1016/j.injury.2011.06.024
- Mohd Jani, J., Leary, M., Subic, A., & Gibson, M. A. (2014). A review of shape memory alloy research, applications and opportunities. Materials & Design (1980-2015), 56, 1078–1113. https://doi.org/10.1016/j.matdes.2013.11.084
- Kujala, S., Ryhänen, J., Jämsä, T., Danilov, A., Saaranen, J., Pramila, A., & Tuukkanen, J. (2002). Bone modeling controlled by a nickel–titanium shape memory alloy intramedullary nail. Biomaterials, 23(12), 2535–2543. https://doi.org/10.1016/s0142-9612(01)00388-x
- Pfeifer, R., Müller, C. W., Hurschler, C., Kaierle, S., Wesling, V., & Haferkamp, H. (2013). Adaptable Orthopedic Shape Memory Implants. Procedia CIRP, 5, 253–258. https://doi.org/10.1016/j.procir.2013.01.050
- Müller, C. W., Pfeifer, R., El‐Kashef, T., Hurschler, C., Herzog, D., Oszwald, M., Haasper, C., Krettek, C., & Gösling, T. (2010). Electromagnetic induction heating of an orthopaedic nickel–titanium shape memory device. Journal of Orthopaedic Research, 28(12), 1671–1676. https://doi.org/10.1002/jor.21171
- Levitt, A. B., Robinson, K., Chronos, N. A. F., & Daum, W. (2003). External heating of stents by radio waves. Cardiovascular Radiation Medicine, 4(3), 133–138. https://doi.org/10.1016/s1522-1865(03)00166-5
- Kawakita, E., Wang, Z., Kato, T., Inaba, T., & Kasai, Y. (2012). Basic Research on a Cylindrical Implant Made of Shape-Memory Alloy for the Treatment of Long Bone Fracture. The Open Orthopaedics Journal, 6(1), 239–244. https://doi.org/10.2174/1874325001206010239
- Lundskog J (1972) Heat and bone tissue. an experimental investigation of the thermal properties of bone and threshold levels for thermal injury. Scand J Plast Reconstr Surg 9:1–80
- Eriksson, A., Albrektsson, T., Grane, B., & McQueen, D. (1982). Thermal injury to bone. International Journal of Oral Surgery, 11(2), 115–121. https://doi.org/10.1016/s0300-9785(82)80020-3
- Bekyarova G, Tancheva S, Hristova M (2009) Protective effect of melatonin against oxidative hepatic injury after experimental thermal trauma. Methods Find Exp Clin Pharmacol 31:11–14. doi: 10.1358/mf.2009.31.1.1338411 https://doi.org/10.1358/mf.2009.31.1.1346609
- Ryh�nen, J., Kallioinen, M., Tuukkanen, J., Junila, J., Niemel�, E., Sandvik, P., & Serlo, W. (1998). In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: Muscle and perineural tissue responses and encapsule membrane thickness. Journal of Biomedical Materials Research, 41(3), 481–488. https://doi.org/10.1002/(sici)1097-4636(19980905)41:3%3C481::aid-jbm19%3E3.0.co;2-l
- Ryh�nen, J., Kallioinen, M., Serlo, W., Per�m�ki, P., Junila, J., Sandvik, P., Niemel�, E., & Tuukkanen, J. (1999). Bone healing and mineralization, implant corrosion, and trace metals after nickel-titanium shape memory metal intramedullary fixation. Journal of Biomedical Materials Research, 47(4), 472–480. https://doi.org/10.1002/(sici)1097-4636(19991215)47:4%3C472::aid-jbm3%3E3.0.co;2-z
- Hildebrand, F., Pape, H.-C., Hoevel, P., Krettek, C., & van Griensven, M. (2003). The Importance of Systemic Cytokines in the Pathogenesis of Polymicrobial Sepsis and Dehydroepiandrosterone Treatment in a Rodent Model. Shock, 20(4), 338–346. https://doi.org/10.1097/01.shk.0000081408.57952.22
- Gauglitz, G. G., Song, J., Herndon, D. N., Finnerty, C. C., Boehning, D., Barral, J. M., & Jeschke, M. G. (2008). CHARACTERIZATION OF THE INFLAMMATORY RESPONSE DURING ACUTE AND POST-ACUTE PHASES AFTER SEVERE BURN. Shock, 30(5), 503–507. https://doi.org/10.1097/shk.0b013e31816e3373
- Morita, Y., Oda, S., Sadahiro, T., Nakamura, M., Oshima, T., Otani, S., & Hirasawa, H. (2009). The effects of body temperature control on cytokine production in a rat model of ventilator-induced lung injury. Cytokine, 47(1), 48–55. https://doi.org/10.1016/j.cyto.2009.04.004
1–25 of 30
Citations
- Nadeem, S., Vásquez Peña, M., Ho, C.-H., Gaudreau, A., Nikolov, H., Holdsworth, D. W., Heinrichs, D. E., & Gillies, E. R. (2026). Combination antibiotic-loaded poly(ester amide) coatings and induction heating for bacterial killing on metal surfaces. RSC Applied Polymers, 4(5), 1722–1734. https://doi.org/10.1039/d6lp00244g
- Ansari, S. R., Grimm, D., Ramachandran, R. V., Suárez-López, Y. del C., Juriga-Tóth, K., Sotiriou, G. A., & Teleki, A. (2025). Magnetic microfiber hyperthermia for synergistic antimicrobial activity against methicillin-resistant Staphylococcus aureus. Materials Today Bio, 32, Article 101862. https://doi.org/10.1016/j.mtbio.2025.101862
- Irmak Šalandová, M., Fratila-Apachitei, L. E., Apachitei, I., & Zadpoor, A. A. (2025). Alternating magnetic field and induction heating as antibacterial therapy in implant-associated infections. International Journal of Hyperthermia, 42(1). https://doi.org/10.1080/02656736.2025.2563301
- Evers, P., Suhr, T., Reulbach, M., Emonde, C., Jakubowitz, E., Windhagen, H., & Nürnberger, F. (2024). Characterization and Modeling of the Inductive Heating of CoCrMo Hip Implants to Facilitate Intentional Removal. 2024 IEEE International Symposium on Medical Measurements and Applications (MeMeA), 1–6. https://doi.org/10.1109/memea60663.2024.10596835
- Kwan, J. C., Flannagan, R. S., Vásquez Peña, M., Heinrichs, D. E., Holdsworth, D. W., & Gillies, E. R. (2023). Induction Heating Triggers Antibiotic Release and Synergistic Bacterial Killing on Polymer‐Coated Titanium Surfaces. Advanced Healthcare Materials, 12(22). https://doi.org/10.1002/adhm.202202807
- Pijls, B. G., Sanders, I. M. J. G., Kuijper, E. J., & Nelissen, R. G. H. H. (2022). Effectiveness of mechanical cleaning, antibiotics, and induction heating on eradication of Staphylococcus aureus in mature biofilms. Bone & Joint Research, 11(9), 629–638. https://doi.org/10.1302/2046-3758.119.bjr-2022-0010.r1
- Ciarolla, A. A., Lapin, N., Williams, D., Chopra, R., & Greenberg, D. E. (2022). Physical Approaches to Prevent and Treat Bacterial Biofilm. Antibiotics, 12(1), 54. https://doi.org/10.3390/antibiotics12010054
- Hou, Z., Liu, Z., Zhu, X., Xie, Y., Yan, F., Yin, H., Zhang, Z., Wu, M., Liang, X., Deng, Z., Hu, C., Xiao, K., Chen, S., Chen, Y., Wu, Z., Gu, X., Sun, Q., Ni, B., & Cai, L. (2020). Contactless treatment for scoliosis by electromagnetically controlled shape-memory alloy rods: a preliminary study in rabbits. European Spine Journal, 29(5), 1147–1158. https://doi.org/10.1007/s00586-019-06207-7
- Pijls, B. G., Sanders, I. M. J. G., Kuijper, E. J., & Nelissen, R. G. H. H. (2020). Synergy between induction heating, antibiotics, and N-acetylcysteine eradicates Staphylococcus aureus from biofilm. International Journal of Hyperthermia, 37(1), 130–136. https://doi.org/10.1080/02656736.2019.1710269
- Pijls, B. G., Sanders, I. M. J. G., Kujiper, E. J., & Nelissen, R. G. H. H. (2020). Induction heating for eradicating Staphylococcus epidermidis from biofilm. Bone & Joint Research, 9(4), 192–199. https://doi.org/10.1302/2046-3758.94.bjr-2019-0274.r1
- Mani Prabu, S. S., R, M., Muralidharan, M., Nath, T., A, B., Akash, K., & Palani, I. A. (2019). Thermo-mechanical behavior of shape memory alloy spring actuated using novel scanning technique powered by ytterbium doped continuous fiber laser. Smart Materials and Structures, 28(4), 047001. https://doi.org/10.1088/1361-665x/ab06d8
- Rosa, N., Marta, M., Vaz, M., Tavares, S. M. O., Simoes, R., Magalhães, F. D., & Marques, A. T. (2019). Intramedullary nailing biomechanics: Evolution and challenges. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 233(3), 295–308. https://doi.org/10.1177/0954411919827044
- Pijls, B. G., Sanders, I. M. J. G., Kuijper, E. J., & Nelissen, R. G. H. H. (2018). Segmental induction heating of orthopaedic metal implants. Bone & Joint Research, 7(11), 609–619. https://doi.org/10.1302/2046-3758.711.bjr-2018-0080.r1
- Krämer, M., Müller, C. W., Hermann, M., Decker, S., Springer, A., Overmeyer, L., Hurschler, C., & Pfeifer, R. (2017). Design considerations for a novel shape-memory-plate osteosynthesis allowing for non-invasive alteration of bending stiffness. Journal of the Mechanical Behavior of Biomedical Materials, 75, 558–566. https://doi.org/10.1016/j.jmbbm.2017.08.024
- Pijls, B. G., Sanders, I. M. J. G., Kuijper, E. J., & Nelissen, R. G. H. H. (2017). Non-contact electromagnetic induction heating for eradicating bacteria and yeasts on biomaterials and possible relevance to orthopaedic implant infections. Bone & Joint Research, 6(5), 323–330. https://doi.org/10.1302/2046-3758.65.bjr-2016-0308.r1
- Müller, C. W., Pfeifer, R., Meier, K., Decker, S., Reifenrath, J., Gösling, T., Wesling, V., Krettek, C., Hurschler, C., & Krämer, M. (2015). A Novel Shape Memory Plate Osteosynthesis for Noninvasive Modulation of Fixation Stiffness in a Rabbit Tibia Osteotomy Model. BioMed Research International, 2015, 1–8. https://doi.org/10.1155/2015/652940