Published September 6, 2024 | Journal article | Version v1 | https://doi.org/10.3389/fauot.2024.1456413

Enhancing speech perception in challenging acoustic scenarios for cochlear implant users through automatic signal processing

Description

ObjectivesThis clinical study investigated the impact of the Naída M hearing system, a novel cochlear implant sound processor and corresponding hearing aid, featuring automatic scene classification systems which combine directional microphones and noise reduction algorithms, on speech perception in various acoustic scenarios.MethodsSpeech perception was assessed in 20 cochlear implant (CI) recipients, comprising both bilaterally implanted and bimodal listeners. Participants underwent the adaptive matrix sentence test in both quiet and noisy environments. The automatic scene classifier (ASC, AutoSense OS 3.0) involving different microphone settings was evaluated against the omni-directional microphone on the Naída M hearing system. The predecessor hearing system Naída Q served as reference. Furthermore, the automatic focus steering feature (FSF, Speech in 360°) of the Naída M hearing system was compared to the manual FSF of the Naída Q hearing system in a multi-loudspeaker setup.ResultsWhile both sound processor models yielded comparable outcomes with the omni-directional microphone, the automatic programs demonstrated an enhancement in speech perception: up to 5 dB or 40% in noise for the latest sound processor relative to its predecessor. Subjective feedback further underscored the positive experience with the newer generation system in everyday listening scenarios.ConclusionThe Naída M hearing system features advanced classification systems combined with superior processing capabilities, significantly enhancing speech perception in noisy environments compared to its predecessor, the Naída Q hearing system.

Additional details

Dates

Issued
September 6, 2024

References

  1. Appleton-HuberJ. AutoSense OS Benefit of the Next Generation of Technology Automatio2015
  2. Bentler, R. A. (2005). Effectiveness of Directional Microphones and Noise Reduction Schemes in Hearing Aids: A Systematic Review of the Evidence. Journal of the American Academy of Audiology, 16(7), 473–484. https://doi.org/10.3766/jaaa.16.7.7
  3. Buechner, A., Brendel, M., Saalfeld, H., Litvak, L., Frohne-Buechner, C., & Lenarz, T. (2010). Results of a Pilot Study With a Signal Enhancement Algorithm for HiRes 120 Cochlear Implant Users. Otology & Neurotology, 31(9), 1386–1390. https://doi.org/10.1097/mao.0b013e3181f1cdc6
  4. Buechner, A., Dyballa, K.-H., Hehrmann, P., Fredelake, S., Lenarz, T., & Wanunu, M. (2014). Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions. PLoS ONE, 9(4), e95542. https://doi.org/10.1371/journal.pone.0095542
  5. "Simulating pinna effect by use of the Real Ear Sound algorithm in Advanced Bionics CI recipients,"
  6. Chung, K., Zeng, F.-G., & Acker, K. N. (2006). Effects of directional microphone and adaptive multichannel noise reduction algorithm on cochlear implant performance. The Journal of the Acoustical Society of America, 120(4), 2216–2227. https://doi.org/10.1121/1.2258500
  7. Cord, M. T., Surr, R. K., Walden, B. E., & Olson, L. (2002). Performance of Directional Microphone Hearing Aids in Everyday Life. Journal of the American Academy of Audiology, 13(06), 295–307. https://doi.org/10.1055/s-0040-1715973
  8. Devocht, E. M. J., Janssen, A. M. L., Chalupper, J., Stokroos, R. J., George, E. L. J., & Larson, C. R. (2016). Monaural Beamforming in Bimodal Cochlear Implant Users: Effect of (A)symmetric Directivity and Noise Type. PLOS ONE, 11(8), e0160829. https://doi.org/10.1371/journal.pone.0160829
  9. Dingemanse, J. G., Vroegop, J. L., & Goedegebure, A. (2018). Effects of a transient noise reduction algorithm on speech intelligibility in noise, noise tolerance and perceived annoyance in cochlear implant users. International Journal of Audiology, 57(5), 360–369. https://doi.org/10.1080/14992027.2018.1425004
  10. Dyballa, K.-H., Hehrmann, P., Hamacher, V., Nogueira, W., Lenarz, T., & Büchner, A. (2015). Evaluation of A Transient Noise Reduction Algorithm in Cochlear Implant Users. Audiology Research, 5(2), 116. https://doi.org/10.4081/audiores.2015.116
  11. Eichenauer, A., Baumann, U., Stöver, T., & Weissgerber, T. (2021). Interleaved Acoustic Environments: Impact of an Auditory Scene Classification Procedure on Speech Perception in Cochlear Implant Users. Trends in Hearing, 25. https://doi.org/10.1177/23312165211014118
  12. Ernst, A., Anton, K., Brendel, M., & Battmer, R.-D. (2019). Benefit of directional microphones for unilateral, bilateral and bimodal cochlear implant users. Cochlear Implants International, 20(3), 147–157. https://doi.org/10.1080/14670100.2019.1578911
  13. Frohne-Büchner, C., Büchner, A., Gärtner, L., Battmer, R. D., & Lenarz, T. (2004). Experience of uni- and bilateral cochlear implant users with a microphone positioned in the pinna. International Congress Series, 1273, 93–96. https://doi.org/10.1016/j.ics.2004.08.047
  14. Gatehouse, S., & Noble, W. (2004). The Speech, Spatial and Qualities of Hearing Scale (SSQ). International Journal of Audiology, 43(2), 85–99. https://doi.org/10.1080/14992020400050014
  15. Geißler, G., Arweiler, I., Hehrmann, P., Lenarz, T., Hamacher, V., & Büchner, A. (2014). Speech reception threshold benefits in cochlear implant users with an adaptive beamformer in real life situations. Cochlear Implants International, 16(2), 69–76. https://doi.org/10.1179/1754762814y.0000000088
  16. Gifford, R. H., & Revit, L. J. (2010). Speech Perception for Adult Cochlear Implant Recipients in a Realistic Background Noise: Effectiveness of Preprocessing Strategies and External Options for Improving Speech Recognition in Noise. Journal of the American Academy of Audiology, 21(7), 441–451. https://doi.org/10.3766/jaaa.21.7.3
  17. Holtmann, L. C., Janosi, A., Bagus, H., Scholz, T., Lang, S., Arweiler-Harbeck, D., & Hans, S. (2020). Aligning Hearing Aid and Cochlear Implant Improves Hearing Outcome in Bimodal Cochlear Implant Users. Otology & Neurotology, 41(10), 1350–1356. https://doi.org/10.1097/mao.0000000000002796
  18. Kolberg, E. R., Sheffield, S. W., Davis, T. J., Sunderhaus, L. W., & Gifford, R. H. (2015). Cochlear Implant Microphone Location Affects Speech Recognition in Diffuse Noise. Journal of the American Academy of Audiology, 26(1), 51–58. https://doi.org/10.3766/jaaa.26.1.6
  19. Marcrum, S. C., Picou, E. M., Bohr, C., & Steffens, T. (2021). Activating a Noise-Gating Algorithm and Personalizing Electrode Threshold Levels Improve Recognition of Soft Speech for Adults With CIs. Ear & Hearing, 42(5), 1208–1217. https://doi.org/10.1097/aud.0000000000001003
  20. Mauger, S. J., Warren, C. D., Knight, M. R., Goorevich, M., & Nel, E. (2014). Clinical evaluation of the Nucleus®6 cochlear implant system: Performance improvements with SmartSound iQ. International Journal of Audiology, 53(8), 564–576. https://doi.org/10.3109/14992027.2014.895431
  21. Mosnier, I., Mathias, N., Flament, J., Amar, D., Liagre-Callies, A., Borel, S., Ambert-Dahan, E., Sterkers, O., & Bernardeschi, D. (2017). Benefit of the UltraZoom beamforming technology in noise in cochlear implant users. European Archives of Oto-Rhino-Laryngology, 274(9), 3335–3342. https://doi.org/10.1007/s00405-017-4651-3
  22. Nelson, P. B., Jin, S.-H., Carney, A. E., & Nelson, D. A. (2003). Understanding speech in modulated interference: Cochlear implant users and normal-hearing listeners. The Journal of the Acoustical Society of America, 113(2), 961–968. https://doi.org/10.1121/1.1531983
  23. Noble, W., Jensen, N. S., Naylor, G., Bhullar, N., & Akeroyd, M. A. (2013). A short form of the Speech, Spatial and Qualities of Hearing scale suitable for clinical use: The SSQ12. International Journal of Audiology, 52(6), 409–412. https://doi.org/10.3109/14992027.2013.781278
  24. Potts, L. G., Jang, S., & Hillis, C. L. (2021). Evaluation of Automatic Directional Processing with Cochlear Implant Recipients. Journal of the American Academy of Audiology, 32(8), 478–486. https://doi.org/10.1055/s-0041-1733967
  25. Rak, K., Schraven, S. P., Schendzielorz, P., Kurz, A., Shehata-Dieler, W., Hagen, R., & Radeloff, A. (2017). Stable Longitudinal Performance of Adult Cochlear Implant Users for More Than 10 Years. Otology & Neurotology, 38(9), e315–e319. https://doi.org/10.1097/mao.0000000000001516

1–25 of 35