Range of motion assessment of the shoulder and elbow joints using a motion sensing input device: A pilot study
Authors/Creators
-
1.
Medizinische Hochschule Hannover
-
2.
Hochschule Hannover
- 3. Trauma Department, Hannover Medical School (MHH), Hannover, Germany
Additional details
Identifiers
- OpenAlex
- W1585489058
- PMID
- 24898866
- URL
- https://journals.sagepub.com/doi/full/10.3233/THC-140831
Dates
- Issued
-
April 1, 2014
Citations
- Virani, S., Abdelghafour, K. M., Assiotis, A., Yeoh, C., Rumian, A., & Uppal, H. (2025). Mid-term outcomes of elbow hemiarthroplasty using the triceps-on approach for comminuted distal humerus fractures. Journal of Clinical Orthopaedics and Trauma, 61, 102886. https://doi.org/10.1016/j.jcot.2024.102886
- https://doi.org/10.3390/s25030667
- https://doi.org/10.3390/s25071960
- Ryu, S. M., Shin, K., Doh, C. H., Ben, H., Park, J. Y., Koh, K.-H., Shin, H., & Jeon, I.-. ho . (2024). Orthopedic surgeon level joint angle assessment with artificial intelligence based on photography: a pilot study. Biomedical Engineering Letters, 15(1), 131–142. https://doi.org/10.1007/s13534-024-00432-w
- https://doi.org/10.1109/cloud-summit61220.2024.00011
- https://doi.org/10.1109/jsen.2024.3376654
- https://doi.org/10.9746/sicetr.60.604
- Latreche, A., Kelaiaia, R., Chemori, A., & Kerboua, A. (2023). Reliability and validity analysis of MediaPipe-based measurement system for some human rehabilitation motions. Measurement, 214, Article 112826. https://doi.org/10.1016/j.measurement.2023.112826
- https://doi.org/10.1177/17585732231195554
- https://doi.org/10.3233/thc-220727
- https://doi.org/10.56984/8zg20adec
- https://doi.org/10.5937/fk77-46799
- Rezende, A. R., Alves, C. M., Marques, I. A., Silva, D. C., Paiva, T. S., & Naves, E. L. M. (2022). Technologies Applied for Elbow Joint Angle Measurements: A Systematic Review. In IFMBE Proceedings (pp. 245–250). Springer International Publishing. https://doi.org/10.1007/978-3-030-70601-2_39
- Mangal, N. K., & Tiwari, A. K. (2021). A review of the evolution of scientific literature on technology-assisted approaches using RGB-D sensors for musculoskeletal health monitoring. Computers in Biology and Medicine, 132, 104316. https://doi.org/10.1016/j.compbiomed.2021.104316
- https://doi.org/10.3390/s21248186
- https://doi.org/10.4055/jkoa.2021.56.1.68
- Steinebach, T., Grosse, E. H., Glock, C. H., Wakula, J., & Lunin, A. (2020). Accuracy evaluation of two markerless motion capture systems for measurement of upper extremities: Kinect V2 and Captiv. Human Factors and Ergonomics in Manufacturing & Service Industries, 30(4), 291–302. https://doi.org/10.1002/hfm.20840
- https://doi.org/10.3390/s20247238
- https://doi.org/10.1145/3340037.3340061
- https://doi.org/10.1155/2018/7906875
- https://doi.org/10.3390/s18082439
- https://doi.org/10.1109/icorr.2017.8009434
- https://doi.org/10.1177/1758573217728711
- Beshara, P., Chen, J., Lagadec, P., & Walsh, W. R. (2016). Test-Retest and Intra-rater Reliability of Using Inertial Sensors and Its Integration with Microsoft Kinect™ to Measure Shoulder Range-of-Motion. In Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering (pp. 177–184). Springer International Publishing. https://doi.org/10.1007/978-3-319-51234-1_31
- Seo, N. J., Fathi, M. F., Hur, P., & Crocher, V. (2016). Modifying Kinect placement to improve upper limb joint angle measurement accuracy. Journal of Hand Therapy, 29(4), 465–473. https://doi.org/10.1016/j.jht.2016.06.010
1–25 of 31