Published November 2011 | Journal article | Version v1 | https://doi.org/10.1179/1754762811y0000000009

Clinical evaluation of cochlear implant sound coding taking into account conjectural masking functions, MP3000™

Additional details

Dates

Issued
November 2011

References

  1. Abbas, P. J., Hughes, M. L., Brown, C. J., Miller, C. A., & South, H. (2004). Channel Interaction in Cochlear Implant Users Evaluated Using the Electrically Evoked Compound Action Potential. Audiology and Neurotology, 9(4), 203–213. https://doi.org/10.1159/000078390
  2. Büchner, A., Nogueira, W., Edler, B., Battmer, R.-D., & Lenarz, T. (2008). Results from a Psychoacoustic Model-Based Strategy for the Nucleus-24 and Freedom Cochlear Implants. Otology & Neurotology, 29(2), 189–192. https://doi.org/10.1097/mao.0b013e318162512c
  3. Buechner, A., Frohne-Buechner, C., Boyle, P., Battmer, R.-D., & Lenarz, T. (2009). A high rate n-of-m speech processing strategy for the first generation Clarion cochlear implant. International Journal of Audiology, 48(12), 868–875. https://doi.org/10.3109/14992020903095783
  4. Cohen, L. T. (2009). Practical model description of peripheral neural excitation in cochlear implant recipients: 2. Spread of the effective stimulation field (ESF), from ECAP and FEA. Hearing Research, 247(2), 100–111. https://doi.org/10.1016/j.heares.2008.11.004
  5. Cohen, L. T., Saunders, E., & Richardson, L. M. (2004). Spatial spread of neural excitation: comparison of compound action potential and forward-masking data in cochlear implant recipients. International Journal of Audiology, 43(6), 346–355. https://doi.org/10.1080/14992020400050044
  6. Cohen, L. T., Lenarz, T., Battmer, R.-D., Bender von Saebelkampf, C., Busby, P. A., & Cowan, R. S. C. (2005). A psychophysical forward masking comparison of longitudinal spread of neural excitation in the Contour™ and straight Nucleus® electrode arrays. International Journal of Audiology, 44(10), 559–566. https://doi.org/10.1080/14992020500258743
  7. Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997). Speech Recognition as a Function of the Number of Electrodes Used in the SPEAK Cochlear Implant Speech Processor. Journal of Speech, Language, and Hearing Research, 40(5), 1201–1215. https://doi.org/10.1044/jslhr.4005.1201
  8. Friesen, L. M., Shannon, R. V., Baskent, D., & Wang, X. (2001). Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants. The Journal of the Acoustical Society of America, 110(2), 1150–1163. https://doi.org/10.1121/1.1381538
  9. Kals, M., Schatzer, R., Krenmayr, A., Vermeire, K., Visser, D., Bader, P., Neustetter, C., Zangerl, M., & Zierhofer, C. (2010). Results with a cochlear implant channel-picking strategy based on “Selected Groups”. Hearing Research, 260(1-2), 63–69. https://doi.org/10.1016/j.heares.2009.11.012
  10. McDermott, H. J., McKay, C. M., & Vandali, A. E. (1992). A new portable sound processor for the University of Melbourne/Nucleus Limited multielectrode cochlear implant. The Journal of the Acoustical Society of America, 91(6), 3367–3371. https://doi.org/10.1121/1.402826
  11. Nogueira, W., Büchner, A., Lenarz, T., & Edler, B. (2005). A Psychoacoustic "NofM"-Type Speech Coding Strategy for Cochlear Implants. EURASIP Journal on Advances in Signal Processing, 2005(18). https://doi.org/10.1155/asp.2005.3044
  12. Plant, K. L., Whitford, L. A., Psarros, C. E., & Vandali, A. E. (2002). Parameter selection and programming recommendations for the ACE and CIS speech-processing strategies in the Nucleus 24 cochlear implant system. Cochlear Implants International, 3(2), 104–125. https://doi.org/10.1179/cim.2002.3.2.104
  13. Van Weert, S., Stokroos, R. J., Rikers, M. M. J. G., & Van Dijk, P. (2005). Effect of peri-modiolar cochlear implant positioning on auditory nerve responses: A neural response telemetry study. Acta Oto-Laryngologica, 125(7), 725–731. https://doi.org/10.1080/00016480510028492
  14. Wilson, B. C., Davidson, B., Corey, J. P., & Haydon, R. C. (1988). Comparison of complications following frontal sinus fractures managed with exploration with or without obliteration over 10 years. The Laryngoscope, 98(5), 516–520. https://doi.org/10.1288/00005537-198805000-00008
  15. Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991). Better speech recognition with cochlear implants. Nature, 352(6332), 236–238. https://doi.org/10.1038/352236a0
  16. Ziese, M., Stützel, A., von Specht, H., Begall, K., Freigang, B., Sroka, S., & Nopp, P. (2000). Speech Understanding with the CIS and the n-of-m Strategy in the MED-EL COMBI 40+ System. ORL, 62(6), 321–329. https://doi.org/10.1159/000027763

Citations

  1. https://doi.org/10.1097/aud.0000000000001741
  2. https://doi.org/10.1146/annurev-bioeng-102623-121249
  3. https://doi.org/10.2139/ssrn.5006589
  4. https://doi.org/10.1055/a-2123-4315
  5. https://doi.org/10.1109/usbereit58508.2023.10158841
  6. https://doi.org/10.1121/10.0019416
  7. https://doi.org/10.1055/a-1731-9321
  8. Carlyon, R. P., & Goehring, T. (2021). Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update. Journal of the Association for Research in Otolaryngology, 22(5), 481–508. https://doi.org/10.1007/s10162-021-00811-5
  9. https://doi.org/10.1371/journal.pone.0244433
  10. Tabibi, S., Kegel, A., Lai, W. K., & Dillier, N. (2020). A bio-inspired coding (BIC) strategy for cochlear implants. Hearing Research, 388, 107885. https://doi.org/10.1016/j.heares.2020.107885
  11. Lamping, W., Goehring, T., Marozeau, J., & Carlyon, R. P. (2020). The effect of a coding strategy that removes temporally masked pulses on speech perception by cochlear implant users. Hearing Research, 391, Article 107969. https://doi.org/10.1016/j.heares.2020.107969
  12. Bolner, F., Magits, S., van Dijk, B., & Wouters, J. (2020). Precompensating for spread of excitation in a cochlear implant coding strategy. Hearing Research, 395, 107977. https://doi.org/10.1016/j.heares.2020.107977
  13. https://doi.org/10.1097/aud.0000000000000807
  14. https://doi.org/10.1121/1.5031112
  15. https://doi.org/10.4236/jbise.2018.117014
  16. Eggermont, J. J. (2017). Cochlear Implants. In Hearing Loss (pp. 307–347). Elsevier. https://doi.org/10.1016/b978-0-12-805398-0.00011-6
  17. Langner, F., Saoji, A. A., Büchner, A., & Nogueira, W. (2017). Adding simultaneous stimulating channels to reduce power consumption in cochlear implants. Hearing Research, 345, 96–107. https://doi.org/10.1016/j.heares.2017.01.010
  18. Hey, M., Brademann, G., & Ambrosch, P. (2016). Der Freiburger Einsilbertest in der postoperativen CI-Diagnostik. HNO, 64(8), 601–607. https://doi.org/10.1007/s00106-016-0194-y
  19. Hassepass, F., Arndt, S., Aschendorff, A., Laszig, R., & Wesarg, T. (2015). Cochlear implantation for hearing rehabilitation in single-sided deafness after translabyrinthine vestibular schwannoma surgery. European Archives of Oto-Rhino-Laryngology, 273(9), 2373–2383. https://doi.org/10.1007/s00405-015-3801-8
  20. https://doi.org/10.1109/msp.2014.2371671
  21. https://doi.org/10.1177/2331216515616941
  22. https://doi.org/10.3109/14992027.2015.1070309
  23. https://doi.org/10.3109/00016489.2014.884725
  24. Kida, M., Mikołajewska, L., Morawski, K., Lachowska, M., Łukaszewicz, Z., Bieńkowska, K., & Niemczyk, K. (2013). Analiza wyników percepcji słuchowej w nowej strategii MP3000 i konwencjonalnych strategiach kodowania mowy. Polski Przegląd Otorynolaryngologiczny, 2(4), 194–198. https://doi.org/10.1016/j.ppotor.2013.10.003
  25. https://doi.org/10.3109/00016489.2012.753639