Photon-counting CT of elbow joint fractures: image quality in a simulated post-trauma setting with off-center positioning
Description
Abstract Background Photon-counting detector computed tomography (PCD-CT) has the potential to provide superior image quality compared to energy-integrating detector computed tomography (EID-CT). We compared the two systems for elbow imaging in off-center arm positioning, 90° flexion, and cast fixation in a simulated post-trauma setting. Methods The institutional review board approved the study protocol. In a cadaver study, an olecranon fracture was artificially created in ten whole arm specimens. Two different scanning positions were evaluated: (a) arm overhead; and (b) arm on top of the abdomen of a whole-body phantom. The ultra-high resolution mode with three dose protocols and two reconstruction kernels was applied. Two blinded radiologists independently evaluated fracture and trabecular bone delineation. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and cortical sharpness measurements were performed. Cohen κ correlations, Mann-Whitney U and Wilcoxon signed rank tests were used. A p value lower than 0.05 was considered statistically significant. Results Dose-equivalent PCD-CT scans were rated better for fracture and trabecular bone evaluation (p < 0.001). SNR, CNR, and cortical sharpness were higher for all diagnostic (Br76) PCD-CT images (p < 0.001). The arm position had less effect on image quality in the PCD-CT compared to the EID-CT. The use of a sharp bone kernel (Br89) improved image quality ratings for PCD-CT. In the low-dose scan mode, PCD-CT resulted in more diagnostic scans (75%) compared to EID-CT (19%). Conclusions PCD-CT provided superior objective and subjective image quality for fracture and trabecular bone structures delineation of the elbow compared to EID-CT in a typical post-trauma setting. Key points • Photon-counting detector computed tomography (PCD-CT) preserved high image quality in elbow imaging with off-center positions. • PCD-CT was advantageous for bone evaluation in trauma elbows. • PCD-CT ultra-high-resolution mode and very sharp reconstruction kernels facilitated higher image quality.
Additional details
Identifiers
Funding
- Medizinische Hochschule Hannover (MHH)
Dates
- Issued
-
March 27, 2023
References
- Aparisi, M., & Aparisi, F. (2013). The Value of Multislice Computed Tomography in the Diagnosis of Elbow Fractures. Seminars in Musculoskeletal Radiology, 17(05), 437–445. https://doi.org/10.1055/s-0033-1360664
- Gondim Teixeira, P. A., Villani, N., Ait Idir, M., Germain, E., Lombard, C., Gillet, R., & Blum, A. (2021). Ultra-high resolution computed tomography of joints: practical recommendations for acquisition protocol optimization. Quantitative Imaging in Medicine and Surgery, 11(10), 4287–4298. https://doi.org/10.21037/qims-21-217
- Toth, T., Ge, Z., & Daly, M. P. (2007). The influence of patient centering on CT dose and image noise. Medical Physics, 34(7), 3093–3101. https://doi.org/10.1118/1.2748113
- Flohr, T. G., Stierstorfer, K., Süß, C., Schmidt, B., Primak, A. N., & McCollough, C. H. (2007). Novel ultrahigh resolution data acquisition and image reconstruction for multi‐detector row CT. Medical Physics, 34(5), 1712–1723. https://doi.org/10.1118/1.2722872
- Euler, A., Saltybaeva, N., & Alkadhi, H. (2019). How patient off-centering impacts organ dose and image noise in pediatric head and thoracoabdominal CT. European Radiology, 29(12), 6790–6793. https://doi.org/10.1007/s00330-019-06330-5
- Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018). Photon-counting CT: Technical Principles and Clinical Prospects. Radiology, 289(2), 293–312. https://doi.org/10.1148/radiol.2018172656
- Flohr, T., Petersilka, M., Henning, A., Ulzheimer, S., Ferda, J., & Schmidt, B. (2020). Photon-counting CT review. Physica Medica, 79, 126–136. https://doi.org/10.1016/j.ejmp.2020.10.030
- Leng, S., Bruesewitz, M., Tao, S., Rajendran, K., Halaweish, A. F., Campeau, N. G., Fletcher, J. G., & McCollough, C. H. (2019). Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. RadioGraphics, 39(3), 729–743. https://doi.org/10.1148/rg.2019180115
- Euler, A., Higashigaito, K., Mergen, V., Sartoretti, T., Zanini, B., Schmidt, B., Flohr, T. G., Ulzheimer, S., Eberhard, M., & Alkadhi, H. (2021). High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta. Investigative Radiology, 57(2), 115–121. https://doi.org/10.1097/rli.0000000000000816
- Zhou, W., Lane, J. I., Carlson, M. L., Bruesewitz, M. R., Witte, R. J., Koeller, K. K., Eckel, L. J., Carter, R. E., McCollough, C. H., & Leng, S. (2018). Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study. American Journal of Neuroradiology, 39(9), 1733–1738. https://doi.org/10.3174/ajnr.a5768
- Rajendran, K., Petersilka, M., Henning, A., Shanblatt, E. R., Schmidt, B., Flohr, T. G., Ferrero, A., Baffour, F., Diehn, F. E., Yu, L., Rajiah, P., Fletcher, J. G., Leng, S., & McCollough, C. H. (2022). First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology, 303(1), 130–138. https://doi.org/10.1148/radiol.212579
- Rajendran, K., Petersilka, M., Henning, A., Shanblatt, E., Marsh, J., Thorne, J., Schmidt, B., Flohr, T., Fletcher, J., McCollough, C., & Leng, S. (2021). Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience. Physics in Medicine & Biology, 66(20), 205019. https://doi.org/10.1088/1361-6560/ac155e
- Peña, J. A., Klein, L., Maier, J., Damm, T., Schlemmer, H.-P., Engelke, K., Glüer, C.-C., Kachelrieß, M., & Sawall, S. (2022). Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT. Zeitschrift Für Medizinische Physik, 32(4), 403–416. https://doi.org/10.1016/j.zemedi.2022.04.001
- Shannon, C. E. (1949). Communication in the Presence of Noise. Proceedings of the IRE, 37(1), 10–21. https://doi.org/10.1109/jrproc.1949.232969
- Booij, R., Kämmerling, N. F., Oei, E. H. G., Persson, A., & Tesselaar, E. (2023). Assessment of visibility of bone structures in the wrist using normal and half of the radiation dose with photon-counting detector CT. European Journal of Radiology, 159, 110662. https://doi.org/10.1016/j.ejrad.2022.110662
- Mergen, V., Sartoretti, T., Baer-Beck, M., Schmidt, B., Petersilka, M., Wildberger, J. E., Euler, A., Eberhard, M., & Alkadhi, H. (2022). Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT. Investigative Radiology, 57(12), 780–788. https://doi.org/10.1097/rli.0000000000000897
- McHugh, M. L. (2012). Interrater reliability: the kappa statistic. Biochemia Medica, 276–282. https://doi.org/10.11613/bm.2012.031
- Saltybaeva, N., & Alkadhi, H. (2017). Vertical off‐centering affects organ dose in chest CT: Evidence from Monte Carlo simulations in anthropomorphic phantoms. Medical Physics, 44(11), 5697–5704. https://doi.org/10.1002/mp.12519
- Shaffiq Said Rahmat, S. M., Abdul Karim, M. K., Che Isa, I. N., Abd Rahman, M. A., Noor, N. M., & Hoong, N. K. (2020). Effect of miscentering and low-dose protocols on contrast resolution in computed tomography head examination. Computers in Biology and Medicine, 123, 103840. https://doi.org/10.1016/j.compbiomed.2020.103840
- Samei, E., Bakalyar, D., Boedeker, K. L., Brady, S., Fan, J., Leng, S., Myers, K. J., Popescu, L. M., Ramirez Giraldo, J. C., Ranallo, F., Solomon, J., Vaishnav, J., & Wang, J. (2019). Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233. Medical Physics, 46(11). https://doi.org/10.1002/mp.13763
- Eberhard, M., Blüthgen, C., Barth, B. K., Frauenfelder, T., Saltybaeva, N., & Martini, K. (2020). Vertical Off-Centering in Reduced Dose Chest-CT: Impact on Effective Dose and Image Noise Values. Academic Radiology, 27(4), 508–517. https://doi.org/10.1016/j.acra.2019.07.004
- Booij, R., Budde, R. P. J., Dijkshoorn, M. L., & van Straten, M. (2018). Accuracy of automated patient positioning in CT using a 3D camera for body contour detection. European Radiology, 29(4), 2079–2088. https://doi.org/10.1007/s00330-018-5745-z
- Booij, R., van Straten, M., Wimmer, A., & Budde, R. P. J. (2020). Automated patient positioning in CT using a 3D camera for body contour detection: accuracy in pediatric patients. European Radiology, 31(1), 131–138. https://doi.org/10.1007/s00330-020-07097-w
- Saltybaeva, N., Schmidt, B., Wimmer, A., Flohr, T., & Alkadhi, H. (2018). Precise and Automatic Patient Positioning in Computed Tomography. Investigative Radiology, 53(11), 641–646. https://doi.org/10.1097/rli.0000000000000482
- Kunz, A. S., Schmalzl, J., Huflage, H., Luetkens, K. S., Patzer, T. S., Kuhl, P. J., Gruschwitz, P., Petritsch, B., Schmitt, R., Bley, T. A., & Grunz, J.-P. (2023). Twin Robotic Gantry-Free Cone-Beam CT in Acute Elbow Trauma. Radiology, 306(3). https://doi.org/10.1148/radiol.221200
1–25 of 35
Citations
- Peña, J. A., Thomsen, F., Damm, T., Freitag-Wolf, S., Frölich, M., Schönberg, S. O., Schlemmer, H.-P., Engelke, K., Glüer, C.-C., Hövener, J.-B., Jansen, O., Kachelrieß, M., & Sawall, S. (2026). Assessment of trabecular microstructure using photon-counting CT: Influence of dose, spatial resolution and reconstruction algorithms. Bone, Article 118066. https://doi.org/10.1016/j.bone.2026.118066
- Wang, H., Chen, L., Wei, G., Huang, Y., Zhou, Z., Dong, H., Chang, R., Xu, Z., Wu, J., Yu, A., Zeng, D., Li, J., Wang, Y., Du, L., Yan, F., Ye, J., Lu, Y., & Qin, L. (2026). High performance of low-dose ultrahigh-resolution photon-counting detector CT for sacroiliac joint assessment in axial spondyloarthritis. European Journal of Radiology Open, 17, 100815. https://doi.org/10.1016/j.ejro.2026.100815
- Klüner, L. V., Haubold, J., Peuster, H., Ebenau, M., Ocker-Serger, R., Salhöfer, L., Umutlu, L., Forsting, M., Opitz, M., & Zensen, S. (2026). Impact of Vertical Off-centering on Radiation Dose and Image Noise in Photon-counting Computed Tomography. Investigative Radiology, 61(10), 698–705. https://doi.org/10.1097/rli.0000000000001273
- Björkman, A.-S., Malusek, A., Persson, A., Gauffin, H., & Koskinen, S. K. (2026). Photon-counting CT: image quality evaluation in patients with tibial plateau fracture treated with metallic osteosynthesis material. European Radiology Experimental, 10(1). https://doi.org/10.1186/s41747-026-00761-8
- Bärhold, F., Albrecht, T., Hirt, B., Schade-Mann, T., Mühle, A., Schneider, J. M., Afat, S., Brendlin, A., Ernst, B. P., Guchlerner, L., & Becker, S. (2026). Photon-Counting Computed Tomography Enables Image-Guided Navigation of the Paranasal Sinuses at Ultra-Low Radiation Dose: An Initial Cadaveric Study. Diagnostics, 16(20), 3279. https://doi.org/10.3390/diagnostics16203279
- Schwartz, F. R. (2025). Photon-Counting CT in Emergency Radiology. In Clinical Applications of Spectral Photon Counting Computed Tomography Technology (pp. 113–130). Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-85078-3_6
- Lombardo, P., Hartmann, C., Fridle, C., von Tengg-Kobligk, H., Ruder, T. D., & Zech, W.-D. (2025). Diagnostic accuracy of rib fracture detection in forensic post-mortem photon counting CT. International Journal of Legal Medicine, 140(1), 301–309. https://doi.org/10.1007/s00414-025-03597-w
- Zech, W.-D., Herr, N., Schwendener, N., Hartmann, C., von Tengg-Kobligk, H., & Ruder, T. D. (2025). Technical note: An optimized protocol for standard unenhanced whole-body post-mortem Photon Counting CT imaging. Forensic Science International, 367, 112317. https://doi.org/10.1016/j.forsciint.2024.112317
- Ren, L., Duan, X., Ahn, R., Kay, F., Daftaribesheli, L., Zhou, W., Guild, J., & Ananthakrishnan, L. (2025). Photon-counting detector CT: technology overview and radiation dose reduction. British Journal of Radiology, 98(1175), 1788–1801. https://doi.org/10.1093/bjr/tqaf116
- Schwartz, F. R., Sodickson, A. D., Pickhardt, P. J., Sahani, D. V., Lev, M. H., & Gupta, R. (2025). Photon-Counting CT: Technology, Current and Potential Future Clinical Applications, and Overview of Approved Systems and Those in Various Stages of Research and Development. Radiology, 314(3). https://doi.org/10.1148/radiol.240662
- Varga-Szemes, A., & Emrich, T. (2025). Photon-counting detector CT: a disrupting innovation in medical imaging. European Radiology Experimental, 9(1). https://doi.org/10.1186/s41747-025-00571-4
- de Boer, J., Salimova, N., Weidemann, F., Behrendt, L., Werncke, T., Wacker, F. K., & Sonnow, L. (2025). Photon-counting CT versus energy-integrating detector and flat-panel CT for cadaveric wrist arthrography with additional tin filter dose reduction. European Radiology Experimental, 9(1). https://doi.org/10.1186/s41747-025-00604-y
- Wu, P. W., Zhang, D., Primak, A., Booij, R., Winant, A. J., & Lee, E. Y. (2024). Photon-Counting Detector Computed Tomography. Advances in Clinical Radiology, 6(1), 277–288. https://doi.org/10.1016/j.yacr.2024.05.004
- Vosshenrich, J., O'Donnell, T., & Fritz, J. (2024). Photon-Counting CT in Musculoskeletal Imaging—10 Key Questions Answered. Seminars in Roentgenology, 59(4), 378–386. https://doi.org/10.1053/j.ro.2024.05.003
- Bette, S., Risch, F., Becker, J., Popp, D., Decker, J. A., Kaufmann, D., Friedrich, L., Scheurig-Münkler, C., Schwarz, F., & Kröncke, T. J. (2024). Photon-counting detector CT – first experiences in the field of musculoskeletal radiology. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 197(01), 34–43. https://doi.org/10.1055/a-2312-6914
- Ahmad, M. I., Liu, L., Sheikh, A., & Nicolaou, S. (2024). The role of musculoskeletal radiologists in emergency and trauma settings: current and emerging imaging modalities. BJR|Open, 7(1). https://doi.org/10.1093/bjro/tzaf025
- Huflage, H., Hendel, R., Woznicki, P., Conrads, N., Feldle, P., Patzer, T. S., Ergün, S., Bley, T. A., Kunz, A. S., & Grunz, J.-P. (2024). The Small Pixel Effect in Ultra-High-Resolution Photon-Counting CT of the Lumbar Spine. Investigative Radiology, 59(9), 629–634. https://doi.org/10.1097/rli.0000000000001069
- Bette, S. J., Braun, F. M., Luitjens, J. H., Kaufmann, D., Decker, J., Becker, J., Scheurig-Muenkler, C., Kroencke, T. J., & Schwarz, F. (2024). Multiplanar reconstructions of the thoracic spine in a photon counting dual-source CT scanner: comparison to EID-CT. Acta Radiologica, 65(9), 1087–1093. https://doi.org/10.1177/02841851241271109
- Grunz, J.-P., & Huflage, H. (2024). Photon-Counting Computed Tomography: Experience in Musculoskeletal Imaging. Korean Journal of Radiology, 25(7), 662. https://doi.org/10.3348/kjr.2024.0096