Published March 27, 2023 | Journal article | Version v1 | https://doi.org/10.1186/s41747-023-00329-w

Photon-counting CT of elbow joint fractures: image quality in a simulated post-trauma setting with off-center positioning

Description

Abstract Background Photon-counting detector computed tomography (PCD-CT) has the potential to provide superior image quality compared to energy-integrating detector computed tomography (EID-CT). We compared the two systems for elbow imaging in off-center arm positioning, 90° flexion, and cast fixation in a simulated post-trauma setting. Methods The institutional review board approved the study protocol. In a cadaver study, an olecranon fracture was artificially created in ten whole arm specimens. Two different scanning positions were evaluated: (a) arm overhead; and (b) arm on top of the abdomen of a whole-body phantom. The ultra-high resolution mode with three dose protocols and two reconstruction kernels was applied. Two blinded radiologists independently evaluated fracture and trabecular bone delineation. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and cortical sharpness measurements were performed. Cohen κ correlations, Mann-Whitney U and Wilcoxon signed rank tests were used. A p value lower than 0.05 was considered statistically significant. Results Dose-equivalent PCD-CT scans were rated better for fracture and trabecular bone evaluation (p < 0.001). SNR, CNR, and cortical sharpness were higher for all diagnostic (Br76) PCD-CT images (p < 0.001). The arm position had less effect on image quality in the PCD-CT compared to the EID-CT. The use of a sharp bone kernel (Br89) improved image quality ratings for PCD-CT. In the low-dose scan mode, PCD-CT resulted in more diagnostic scans (75%) compared to EID-CT (19%). Conclusions PCD-CT provided superior objective and subjective image quality for fracture and trabecular bone structures delineation of the elbow compared to EID-CT in a typical post-trauma setting. Key points • Photon-counting detector computed tomography (PCD-CT) preserved high image quality in elbow imaging with off-center positions. • PCD-CT was advantageous for bone evaluation in trauma elbows. • PCD-CT ultra-high-resolution mode and very sharp reconstruction kernels facilitated higher image quality.

Additional details

Funding

Medizinische Hochschule Hannover (MHH)

Dates

Issued
March 27, 2023

References

  1. Aparisi, M., & Aparisi, F. (2013). The Value of Multislice Computed Tomography in the Diagnosis of Elbow Fractures. Seminars in Musculoskeletal Radiology, 17(05), 437–445. https://doi.org/10.1055/s-0033-1360664
  2. Gondim Teixeira, P. A., Villani, N., Ait Idir, M., Germain, E., Lombard, C., Gillet, R., & Blum, A. (2021). Ultra-high resolution computed tomography of joints: practical recommendations for acquisition protocol optimization. Quantitative Imaging in Medicine and Surgery, 11(10), 4287–4298. https://doi.org/10.21037/qims-21-217
  3. Toth, T., Ge, Z., & Daly, M. P. (2007). The influence of patient centering on CT dose and image noise. Medical Physics, 34(7), 3093–3101. https://doi.org/10.1118/1.2748113
  4. Flohr, T. G., Stierstorfer, K., Süß, C., Schmidt, B., Primak, A. N., & McCollough, C. H. (2007). Novel ultrahigh resolution data acquisition and image reconstruction for multi‐detector row CT. Medical Physics, 34(5), 1712–1723. https://doi.org/10.1118/1.2722872
  5. Euler, A., Saltybaeva, N., & Alkadhi, H. (2019). How patient off-centering impacts organ dose and image noise in pediatric head and thoracoabdominal CT. European Radiology, 29(12), 6790–6793. https://doi.org/10.1007/s00330-019-06330-5
  6. Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018). Photon-counting CT: Technical Principles and Clinical Prospects. Radiology, 289(2), 293–312. https://doi.org/10.1148/radiol.2018172656
  7. Flohr, T., Petersilka, M., Henning, A., Ulzheimer, S., Ferda, J., & Schmidt, B. (2020). Photon-counting CT review. Physica Medica, 79, 126–136. https://doi.org/10.1016/j.ejmp.2020.10.030
  8. Leng, S., Bruesewitz, M., Tao, S., Rajendran, K., Halaweish, A. F., Campeau, N. G., Fletcher, J. G., & McCollough, C. H. (2019). Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. RadioGraphics, 39(3), 729–743. https://doi.org/10.1148/rg.2019180115
  9. Euler, A., Higashigaito, K., Mergen, V., Sartoretti, T., Zanini, B., Schmidt, B., Flohr, T. G., Ulzheimer, S., Eberhard, M., & Alkadhi, H. (2021). High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta. Investigative Radiology, 57(2), 115–121. https://doi.org/10.1097/rli.0000000000000816
  10. Zhou, W., Lane, J. I., Carlson, M. L., Bruesewitz, M. R., Witte, R. J., Koeller, K. K., Eckel, L. J., Carter, R. E., McCollough, C. H., & Leng, S. (2018). Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study. American Journal of Neuroradiology, 39(9), 1733–1738. https://doi.org/10.3174/ajnr.a5768
  11. Rajendran, K., Petersilka, M., Henning, A., Shanblatt, E. R., Schmidt, B., Flohr, T. G., Ferrero, A., Baffour, F., Diehn, F. E., Yu, L., Rajiah, P., Fletcher, J. G., Leng, S., & McCollough, C. H. (2022). First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology, 303(1), 130–138. https://doi.org/10.1148/radiol.212579
  12. Rajendran, K., Petersilka, M., Henning, A., Shanblatt, E., Marsh, J., Thorne, J., Schmidt, B., Flohr, T., Fletcher, J., McCollough, C., & Leng, S. (2021). Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience. Physics in Medicine & Biology, 66(20), 205019. https://doi.org/10.1088/1361-6560/ac155e
  13. Peña, J. A., Klein, L., Maier, J., Damm, T., Schlemmer, H.-P., Engelke, K., Glüer, C.-C., Kachelrieß, M., & Sawall, S. (2022). Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT. Zeitschrift Für Medizinische Physik, 32(4), 403–416. https://doi.org/10.1016/j.zemedi.2022.04.001
  14. Shannon, C. E. (1949). Communication in the Presence of Noise. Proceedings of the IRE, 37(1), 10–21. https://doi.org/10.1109/jrproc.1949.232969
  15. Booij, R., Kämmerling, N. F., Oei, E. H. G., Persson, A., & Tesselaar, E. (2023). Assessment of visibility of bone structures in the wrist using normal and half of the radiation dose with photon-counting detector CT. European Journal of Radiology, 159, 110662. https://doi.org/10.1016/j.ejrad.2022.110662
  16. Mergen, V., Sartoretti, T., Baer-Beck, M., Schmidt, B., Petersilka, M., Wildberger, J. E., Euler, A., Eberhard, M., & Alkadhi, H. (2022). Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT. Investigative Radiology, 57(12), 780–788. https://doi.org/10.1097/rli.0000000000000897
  17. McHugh, M. L. (2012). Interrater reliability: the kappa statistic. Biochemia Medica, 276–282. https://doi.org/10.11613/bm.2012.031
  18. Saltybaeva, N., & Alkadhi, H. (2017). Vertical off‐centering affects organ dose in chest CT: Evidence from Monte Carlo simulations in anthropomorphic phantoms. Medical Physics, 44(11), 5697–5704. https://doi.org/10.1002/mp.12519
  19. Shaffiq Said Rahmat, S. M., Abdul Karim, M. K., Che Isa, I. N., Abd Rahman, M. A., Noor, N. M., & Hoong, N. K. (2020). Effect of miscentering and low-dose protocols on contrast resolution in computed tomography head examination. Computers in Biology and Medicine, 123, 103840. https://doi.org/10.1016/j.compbiomed.2020.103840
  20. Samei, E., Bakalyar, D., Boedeker, K. L., Brady, S., Fan, J., Leng, S., Myers, K. J., Popescu, L. M., Ramirez Giraldo, J. C., Ranallo, F., Solomon, J., Vaishnav, J., & Wang, J. (2019). Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233. Medical Physics, 46(11). https://doi.org/10.1002/mp.13763
  21. Eberhard, M., Blüthgen, C., Barth, B. K., Frauenfelder, T., Saltybaeva, N., & Martini, K. (2020). Vertical Off-Centering in Reduced Dose Chest-CT: Impact on Effective Dose and Image Noise Values. Academic Radiology, 27(4), 508–517. https://doi.org/10.1016/j.acra.2019.07.004
  22. Booij, R., Budde, R. P. J., Dijkshoorn, M. L., & van Straten, M. (2018). Accuracy of automated patient positioning in CT using a 3D camera for body contour detection. European Radiology, 29(4), 2079–2088. https://doi.org/10.1007/s00330-018-5745-z
  23. Booij, R., van Straten, M., Wimmer, A., & Budde, R. P. J. (2020). Automated patient positioning in CT using a 3D camera for body contour detection: accuracy in pediatric patients. European Radiology, 31(1), 131–138. https://doi.org/10.1007/s00330-020-07097-w
  24. Saltybaeva, N., Schmidt, B., Wimmer, A., Flohr, T., & Alkadhi, H. (2018). Precise and Automatic Patient Positioning in Computed Tomography. Investigative Radiology, 53(11), 641–646. https://doi.org/10.1097/rli.0000000000000482
  25. Kunz, A. S., Schmalzl, J., Huflage, H., Luetkens, K. S., Patzer, T. S., Kuhl, P. J., Gruschwitz, P., Petritsch, B., Schmitt, R., Bley, T. A., & Grunz, J.-P. (2023). Twin Robotic Gantry-Free Cone-Beam CT in Acute Elbow Trauma. Radiology, 306(3). https://doi.org/10.1148/radiol.221200

1–25 of 35

Citations

  1. Peña, J. A., Thomsen, F., Damm, T., Freitag-Wolf, S., Frölich, M., Schönberg, S. O., Schlemmer, H.-P., Engelke, K., Glüer, C.-C., Hövener, J.-B., Jansen, O., Kachelrieß, M., & Sawall, S. (2026). Assessment of trabecular microstructure using photon-counting CT: Influence of dose, spatial resolution and reconstruction algorithms. Bone, Article 118066. https://doi.org/10.1016/j.bone.2026.118066
  2. Wang, H., Chen, L., Wei, G., Huang, Y., Zhou, Z., Dong, H., Chang, R., Xu, Z., Wu, J., Yu, A., Zeng, D., Li, J., Wang, Y., Du, L., Yan, F., Ye, J., Lu, Y., & Qin, L. (2026). High performance of low-dose ultrahigh-resolution photon-counting detector CT for sacroiliac joint assessment in axial spondyloarthritis. European Journal of Radiology Open, 17, 100815. https://doi.org/10.1016/j.ejro.2026.100815
  3. Klüner, L. V., Haubold, J., Peuster, H., Ebenau, M., Ocker-Serger, R., Salhöfer, L., Umutlu, L., Forsting, M., Opitz, M., & Zensen, S. (2026). Impact of Vertical Off-centering on Radiation Dose and Image Noise in Photon-counting Computed Tomography. Investigative Radiology, 61(10), 698–705. https://doi.org/10.1097/rli.0000000000001273
  4. Björkman, A.-S., Malusek, A., Persson, A., Gauffin, H., & Koskinen, S. K. (2026). Photon-counting CT: image quality evaluation in patients with tibial plateau fracture treated with metallic osteosynthesis material. European Radiology Experimental, 10(1). https://doi.org/10.1186/s41747-026-00761-8
  5. Bärhold, F., Albrecht, T., Hirt, B., Schade-Mann, T., Mühle, A., Schneider, J. M., Afat, S., Brendlin, A., Ernst, B. P., Guchlerner, L., & Becker, S. (2026). Photon-Counting Computed Tomography Enables Image-Guided Navigation of the Paranasal Sinuses at Ultra-Low Radiation Dose: An Initial Cadaveric Study. Diagnostics, 16(20), 3279. https://doi.org/10.3390/diagnostics16203279
  6. Schwartz, F. R. (2025). Photon-Counting CT in Emergency Radiology. In Clinical Applications of Spectral Photon Counting Computed Tomography Technology (pp. 113–130). Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-85078-3_6
  7. Lombardo, P., Hartmann, C., Fridle, C., von Tengg-Kobligk, H., Ruder, T. D., & Zech, W.-D. (2025). Diagnostic accuracy of rib fracture detection in forensic post-mortem photon counting CT. International Journal of Legal Medicine, 140(1), 301–309. https://doi.org/10.1007/s00414-025-03597-w
  8. Zech, W.-D., Herr, N., Schwendener, N., Hartmann, C., von Tengg-Kobligk, H., & Ruder, T. D. (2025). Technical note: An optimized protocol for standard unenhanced whole-body post-mortem Photon Counting CT imaging. Forensic Science International, 367, 112317. https://doi.org/10.1016/j.forsciint.2024.112317
  9. Ren, L., Duan, X., Ahn, R., Kay, F., Daftaribesheli, L., Zhou, W., Guild, J., & Ananthakrishnan, L. (2025). Photon-counting detector CT: technology overview and radiation dose reduction. British Journal of Radiology, 98(1175), 1788–1801. https://doi.org/10.1093/bjr/tqaf116
  10. Schwartz, F. R., Sodickson, A. D., Pickhardt, P. J., Sahani, D. V., Lev, M. H., & Gupta, R. (2025). Photon-Counting CT: Technology, Current and Potential Future Clinical Applications, and Overview of Approved Systems and Those in Various Stages of Research and Development. Radiology, 314(3). https://doi.org/10.1148/radiol.240662
  11. Varga-Szemes, A., & Emrich, T. (2025). Photon-counting detector CT: a disrupting innovation in medical imaging. European Radiology Experimental, 9(1). https://doi.org/10.1186/s41747-025-00571-4
  12. de Boer, J., Salimova, N., Weidemann, F., Behrendt, L., Werncke, T., Wacker, F. K., & Sonnow, L. (2025). Photon-counting CT versus energy-integrating detector and flat-panel CT for cadaveric wrist arthrography with additional tin filter dose reduction. European Radiology Experimental, 9(1). https://doi.org/10.1186/s41747-025-00604-y
  13. Wu, P. W., Zhang, D., Primak, A., Booij, R., Winant, A. J., & Lee, E. Y. (2024). Photon-Counting Detector Computed Tomography. Advances in Clinical Radiology, 6(1), 277–288. https://doi.org/10.1016/j.yacr.2024.05.004
  14. Vosshenrich, J., O'Donnell, T., & Fritz, J. (2024). Photon-Counting CT in Musculoskeletal Imaging—10 Key Questions Answered. Seminars in Roentgenology, 59(4), 378–386. https://doi.org/10.1053/j.ro.2024.05.003
  15. Bette, S., Risch, F., Becker, J., Popp, D., Decker, J. A., Kaufmann, D., Friedrich, L., Scheurig-Münkler, C., Schwarz, F., & Kröncke, T. J. (2024). Photon-counting detector CT – first experiences in the field of musculoskeletal radiology. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 197(01), 34–43. https://doi.org/10.1055/a-2312-6914
  16. Ahmad, M. I., Liu, L., Sheikh, A., & Nicolaou, S. (2024). The role of musculoskeletal radiologists in emergency and trauma settings: current and emerging imaging modalities. BJR|Open, 7(1). https://doi.org/10.1093/bjro/tzaf025
  17. Huflage, H., Hendel, R., Woznicki, P., Conrads, N., Feldle, P., Patzer, T. S., Ergün, S., Bley, T. A., Kunz, A. S., & Grunz, J.-P. (2024). The Small Pixel Effect in Ultra-High-Resolution Photon-Counting CT of the Lumbar Spine. Investigative Radiology, 59(9), 629–634. https://doi.org/10.1097/rli.0000000000001069
  18. Bette, S. J., Braun, F. M., Luitjens, J. H., Kaufmann, D., Decker, J., Becker, J., Scheurig-Muenkler, C., Kroencke, T. J., & Schwarz, F. (2024). Multiplanar reconstructions of the thoracic spine in a photon counting dual-source CT scanner: comparison to EID-CT. Acta Radiologica, 65(9), 1087–1093. https://doi.org/10.1177/02841851241271109
  19. Grunz, J.-P., & Huflage, H. (2024). Photon-Counting Computed Tomography: Experience in Musculoskeletal Imaging. Korean Journal of Radiology, 25(7), 662. https://doi.org/10.3348/kjr.2024.0096