Real-world outcomes of Deep Brain Stimulation for dystonia treatment: Protocol for a prospective, multicenter, international registry
Authors/Creators
Contributors
Editor:
Description
Introduction Deep Brain Stimulation (DBS) is an established therapeutic approach for the treatment of dystonia. However, to date, no large-scale or comprehensive DBS dystonia patient registry has been yet undertaken. Here, we describe the protocol for a world-wide registry of clinical outcomes in dystonia patients implanted with DBS. Methods and analysis This protocol describes a multicenter, international clinical outcomes registry consisting of up to 200 prospectively enrolled participants at up to 40 different sites to be implanted with a constant-current, multiple independent current controlled (MICC) DBS device (Vercise DBS Systems, Boston Scientific) for treatment of dystonia. Key inclusion criteria for registry candidates include the following: understanding of study requirements and treatment procedures, a signed written informed consent form prior to participation, and meeting all criteria established in the locally applicable Instructions for Use (IFU) for the implanted DBS system. Key clinical endpoints include (but are not limited to) the evaluation of disease state (Burke-Fahn-Marsden Dystonia Rating Scale [BFMDRS], Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS), quality of life (Short Form Health Survey-36, Short Form Health Survey-10), and treatment satisfaction (Clinical Global Impression of Change [CGI-Clinician; CGI-Subject; CGI-Caregiver]) at 6-months, 12-months, 2-years, and 3-years post-lead placement. Adverse events are documented and reported using structured questionnaires. Perspectives Treatment of patients with dystonia using DBS has progressed considering recent technological advances. This international dystonia outcomes registry aims to collect and evaluate real-world clinical data derived from patients who have been implanted with a constant-current, MICC-equipped DBS system (with available directional capabilities), per standard of care.
Additional details
Identifiers
- OpenAlex
- W4402917707
- PMID
- 39331655
- URL
- https://dx.plos.org/10.1371/journal.pone.0303381
Dates
- Issued
-
September 27, 2024
References
- Albanese, A., Bhatia, K., Bressman, S. B., DeLong, M. R., Fahn, S., Fung, V. S. C., Hallett, M., Jankovic, J., Jinnah, H. A., Klein, C., Lang, A. E., Mink, J. W., & Teller, J. K. (2013). Phenomenology and classification of dystonia: A consensus update. Movement Disorders, 28(7), 863–873. https://doi.org/10.1002/mds.25475
- Vitek, J. L., Jain, R., Chen, L., Tröster, A. I., Schrock, L. E., House, P. A., Giroux, M. L., Hebb, A. O., Farris, S. M., Whiting, D. M., Leichliter, T. A., Ostrem, J. L., San Luciano, M., Galifianakis, N., Verhagen Metman, L., Sani, S., Karl, J. A., Siddiqui, M. S., Tatter, S. B., … Starr, P. A. (2020). Subthalamic nucleus deep brain stimulation with a multiple independent constant current-controlled device in Parkinson's disease (INTREPID): a multicentre, double-blind, randomised, sham-controlled study. The Lancet Neurology, 19(6), 491–501. https://doi.org/10.1016/s1474-4422(20)30108-3
- Timmermann, L., Jain, R., Chen, L., Maarouf, M., Barbe, M. T., Allert, N., Brücke, T., Kaiser, I., Beirer, S., Sejio, F., Suarez, E., Lozano, B., Haegelen, C., Vérin, M., Porta, M., Servello, D., Gill, S., Whone, A., Van Dyck, N., & Alesch, F. (2015). Multiple-source current steering in subthalamic nucleus deep brain stimulation for Parkinson's disease (the VANTAGE study): a non-randomised, prospective, multicentre, open-label study. The Lancet Neurology, 14(7), 693–701. https://doi.org/10.1016/s1474-4422(15)00087-3
- Koller, W. C., Lyons, K. E., Wilkinson, S. B., Troster, A. I., & Pahwa, R. (2001). Long‐term safety and efficacy of unilateral deep brain stimulation of the thalamus in essential tremor. Movement Disorders, 16(3), 464–468. https://doi.org/10.1002/mds.1089
- Kumar, R., Lozano, A. M., Sime, E., & Lang, A. E. (2003). Long-term follow-up of thalamic deep brain stimulation for essential and parkinsonian tremor. Neurology, 61(11), 1601–1604. https://doi.org/10.1212/01.wnl.0000096012.07360.1c
- Coubes, P., Roubertie, A., Vayssiere, N., Hemm, S., & Echenne, B. (2000). Treatment of DYT1-generalised dystonia by stimulation of the internal globus pallidus. The Lancet, 355(9222), 2220–2221. https://doi.org/10.1016/s0140-6736(00)02410-7
- Krauss, J. K., Pohle, T., Weber, S., Ozdoba, C., & Burgunder, J.-M. (1999). Bilateral stimulation of globus pallidus internus for treatment of cervical dystonia. The Lancet, 354(9181), 837–838. https://doi.org/10.1016/s0140-6736(99)80022-1
- Lozano, A. M., Lipsman, N., Bergman, H., Brown, P., Chabardes, S., Chang, J. W., Matthews, K., McIntyre, C. C., Schlaepfer, T. E., Schulder, M., Temel, Y., Volkmann, J., & Krauss, J. K. (2019). Deep brain stimulation: current challenges and future directions. Nature Reviews Neurology, 15(3), 148–160. https://doi.org/10.1038/s41582-018-0128-2
- Chaturvedi, A., Foutz, T. J., & McIntyre, C. C. (2012). Current steering to activate targeted neural pathways during deep brain stimulation of the subthalamic region. Brain Stimulation, 5(3), 369–377. https://doi.org/10.1016/j.brs.2011.05.002
- Pollo, C., Kaelin-Lang, A., Oertel, M. F., Stieglitz, L., Taub, E., Fuhr, P., Lozano, A. M., Raabe, A., & Schüpbach, M. (2014). Directional deep brain stimulation: an intraoperative double-blind pilot study. Brain, 137(7), 2015–2026. https://doi.org/10.1093/brain/awu102
- Malekmohammadi, M., Mustakos, R., Sheth, S., Pouratian, N., McIntyre, C. C., Bijanki, K. R., Tsolaki, E., Chiu, K., Robinson, M. E., Adkinson, J. A., Oswalt, D., & Carcieri, S. (2022). Automated optimization of deep brain stimulation parameters for modulating neuroimaging-based targets. Journal of Neural Engineering, 19(4), 046014. https://doi.org/10.1088/1741-2552/ac7e6c
- Potel, S. R., Marceglia, S., Meoni, S., Kalia, S. K., Cury, R. G., & Moro, E. (2022). Advances in DBS Technology and Novel Applications: Focus on Movement Disorders. Current Neurology and Neuroscience Reports, 22(9), 577–588. https://doi.org/10.1007/s11910-022-01221-7
- Yianni, J., Bain, P., Giladi, N., Auca, M., Gregory, R., Joint, C., Nandi, D., Stein, J., Scott, R., & Aziz, T. (2003). Globus pallidus internus deep brain stimulation for dystonic conditions: A prospective audit. Movement Disorders, 18(4), 436–442. https://doi.org/10.1002/mds.10380
- Niederländer, C. S., Kriza, C., & Kolominsky-Rabas, P. (2016). Quality criteria for medical device registries: best practice approaches for improving patient safety – a systematic review of international experiences. Expert Review of Medical Devices, 14(1), 49–64. https://doi.org/10.1080/17434440.2017.1268911
- Bisdas, T., Bohan, P., Lescan, M., Zeebregts, C. J., Tessarek, J., van Herwaarden, J., van den Berg, J. C., Setacci, C., & Riambau, V. (2019). Research methodology and practical issues relating to the conduct of a medical device registry. Clinical Trials, 16(5), 490–501. https://doi.org/10.1177/1740774519855395
- Gliklich, R. E., Leavy, M. B., & Dreyer, N. A. (2020). Registries for Evaluating Patient Outcomes: A User's Guide. In L&M Policy Research, LLC, with partners OM1 and IQVIA. Agency for Healthcare Research and Quality (AHRQ). https://doi.org/10.23970/ahrqepcregistries4
- Koy, A., Weinsheimer, M., Pauls, K. A. M., Kühn, A. A., Krause, P., Huebl, J., Schneider, G.-H., Deuschl, G., Erasmi, R., Falk, D., Krauss, J. K., Lütjens, G., Schnitzler, A., Wojtecki, L., Vesper, J., Korinthenberg, R., Coenen, V. A., Visser-Vandewalle, V., Hellmich, M., & Timmermann, L. (2017). German registry of paediatric deep brain stimulation in patients with childhood-onset dystonia (GEPESTIM). European Journal of Paediatric Neurology, 21(1), 136–146. https://doi.org/10.1016/j.ejpn.2016.05.023
- Marks, W., Bailey, L., & Sanger, T. D. (2017). PEDiDBS: The pediatric international deep brain stimulation registry project. European Journal of Paediatric Neurology, 21(1), 218–222. https://doi.org/10.1016/j.ejpn.2016.06.002
- Chan, A.-W., Tetzlaff, J. M., Gotzsche, P. C., Altman, D. G., Mann, H., Berlin, J. A., Dickersin, K., Hrobjartsson, A., Schulz, K. F., Parulekar, W. R., Krleza-Jeric, K., Laupacis, A., & Moher, D. (2013). SPIRIT 2013 explanation and elaboration: guidance for protocols of clinical trials. BMJ, 346(jan08 15), e7586–e7586. https://doi.org/10.1136/bmj.e7586
- Burke, R. E., Fahn, S., Marsden, C. D., Bressman, S. B., Moskowitz, C., & Friedman, J. (1985). Validity and reliability of a rating scale for the primary torsion dystonias. Neurology, 35(1), 73–73. https://doi.org/10.1212/wnl.35.1.73
- Comella, C. L., Leurgans, S., Wuu, J., Stebbins, G. T., Chmura, T., & Group, . and T. D. S. (2002). Rating scales for dystonia: A multicenter assessment. Movement Disorders, 18(3), 303–312. https://doi.org/10.1002/mds.10377
- Nasreddine, Z. S., Phillips, N. A., Bédirian, V., Charbonneau, S., Whitehead, V., Collin, I., Cummings, J. L., & Chertkow, H. (2005). The Montreal Cognitive Assessment, MoCA: A Brief Screening Tool For Mild Cognitive Impairment. Journal of the American Geriatrics Society, 53(4), 695–699. https://doi.org/10.1111/j.1532-5415.2005.53221.x
- Ware, J. E. (2000). SF-36 Health Survey Update. Spine, 25(24), 3130–3139. https://doi.org/10.1097/00007632-200012150-00008
- The Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS): assessment of validity and inter-rater reliability
- Wu, A. D., & Wilson, A. M. (2023). Parkinson's disease population-wide registries in the United States: Current and future opportunities. Frontiers in Digital Health, 5. https://doi.org/10.3389/fdgth.2023.1149154
1–25 of 42