Description
Abbreviated MRI (AMRI) protocols rely on the acquisition of a limited number of sequences tailored to a specific question. The main objective of AMRI protocols is to reduce exam duration and costs, while maintaining an acceptable diagnostic performance. AMRI is of increasing interest in the radiology community; however, challenges limiting clinical adoption remain. In this review, we will address main abdominal and pelvic applications of AMRI in the liver, pancreas, kidney, and prostate, including diagnostic performance, pitfalls, limitations, and cost effectiveness will also be discussed.Level of Evidence: 3Technical Efficacy Stage: 3
Additional details
Identifiers
- OpenAlex
- W4372337426
- PMID
- 37144673
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/jmri.28764
Dates
- Issued
-
May 5, 2023
References
- Thomaides-Brears, H. B., Lepe, R., Banerjee, R., & Duncker, C. (2020). Multiparametric MR mapping in clinical decision-making for diffuse liver disease. Abdominal Radiology, 45(11), 3507–3522. https://doi.org/10.1007/s00261-020-02684-3
- An imaging biomarker for assessing hepatic function in patients with primary sclerosing cholangitis
- Jiang, H., Chen, H. C., Lafata, K. J., & Bashir, M. R. (2021). Week 4 Liver Fat Reduction on MRI as an Early Predictor of Treatment Response in Participants with Nonalcoholic Steatohepatitis. Radiology, 300(2), 361–368. https://doi.org/10.1148/radiol.2021204325
- Hamilton, J., Franson, D., & Seiberlich, N. (2017). Recent advances in parallel imaging for MRI. Progress in Nuclear Magnetic Resonance Spectroscopy, 101, 71–95. https://doi.org/10.1016/j.pnmrs.2017.04.002
- Yoon, J. H., Nickel, M. D., Peeters, J. M., & Lee, J. M. (2019). Rapid Imaging: Recent Advances in Abdominal MRI for Reducing Acquisition Time and Its Clinical Applications. Korean Journal of Radiology, 20(12), 1597. https://doi.org/10.3348/kjr.2018.0931
- Afat, S., Wessling, D., Afat, C., Nickel, D., Arberet, S., Herrmann, J., Othman, A. E., & Gassenmaier, S. (2021). Analysis of a Deep Learning-Based Superresolution Algorithm Tailored to Partial Fourier Gradient Echo Sequences of the Abdomen at 1.5 T. Investigative Radiology, 57(3), 157–162. https://doi.org/10.1097/rli.0000000000000825
- Macari, M., Lee, T., Kim, S., Jacobs, S., Megibow, A. J., Hajdu, C., & Babb, J. (2009). Is Gadolinium Necessary for MRI Follow-Up Evaluation of Cystic Lesions in the Pancreas? Preliminary Results. American Journal of Roentgenology, 192(1), 159–164. https://doi.org/10.2214/ajr.08.1068
- Pozzi-Mucelli, R. M., Rinta-Kiikka, I., Wünsche, K., Laukkarinen, J., Labori, K. J., Ånonsen, K., Verbeke, C., Del Chiaro, M., & Kartalis, N. (2016). Pancreatic MRI for the surveillance of cystic neoplasms: comparison of a short with a comprehensive imaging protocol. European Radiology, 27(1), 41–50. https://doi.org/10.1007/s00330-016-4377-4
- Cunha, G. M., Villela-Nogueira, C. A., Bergman, A., & Lobo Lopes, F. P. P. (2018). Abbreviated mpMRI protocol for diffuse liver disease: a practical approach for evaluation and follow-up of NAFLD. Abdominal Radiology, 43(9), 2340–2350. https://doi.org/10.1007/s00261-018-1504-5
- Tillman, B. G., Gorman, J. D., Hru, J. M., Lee, M. H., King, M. C., Sirlin, C. B., & Marks, R. M. (2018). Diagnostic per-lesion performance of a simulated gadoxetate disodium-enhanced abbreviated MRI protocol for hepatocellular carcinoma screening. Clinical Radiology, 73(5), 485–493. https://doi.org/10.1016/j.crad.2017.11.013
- Weiss, J., Martirosian, P., Notohamiprodjo, M., Kaufmann, S., Othman, A. E., Grosse, U., Nikolaou, K., & Gatidis, S. (2018). Implementation of a 5-Minute Magnetic Resonance Imaging Screening Protocol for Prostate Cancer in Men With Elevated Prostate-Specific Antigen Before Biopsy. Investigative Radiology, 53(3), 186–190. https://doi.org/10.1097/rli.0000000000000427
- van der Leest, M., Israël, B., Cornel, E. B., Zámecnik, P., Schoots, I. G., van der Lelij, H., Padhani, A. R., Rovers, M., van Oort, I., Sedelaar, M., Hulsbergen-van de Kaa, C., Hannink, G., Veltman, J., & Barentsz, J. (2019). High Diagnostic Performance of Short Magnetic Resonance Imaging Protocols for Prostate Cancer Detection in Biopsy-naïve Men: The Next Step in Magnetic Resonance Imaging Accessibility. European Urology, 76(5), 574–581. https://doi.org/10.1016/j.eururo.2019.05.029
- Harvey, S. C., Di Carlo, P. A., Lee, B., Obadina, E., Sippo, D., & Mullen, L. (2016). An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources. Journal of the American College of Radiology, 13(4), 374–380. https://doi.org/10.1016/j.jacr.2015.08.015
- Patient preferences for hepatocellular carcinoma surveillance parameters
- Lima, P. H., Fan, B., Bérubé, J., Cerny, M., Olivié, D., Giard, J.-M., Beauchemin, C., & Tang, A. (2019). Cost-Utility Analysis of Imaging for Surveillance and Diagnosis of Hepatocellular Carcinoma. American Journal of Roentgenology, 213(1), 17–25. https://doi.org/10.2214/ajr.18.20341
- YoonJH RingeKI.Real‐world solutions: Abbreviated MRI in clinical practice. ISMRM. In: Proceedings of the 31st Joint Annual Meeting ISMRM‐ESMRMB & ISMRT London 2022 (abstract).
- Galle, P. R., Forner, A., Llovet, J. M., Mazzaferro, V., Piscaglia, F., Raoul, J.-L., Schirmacher, P., & Vilgrain, V. (2018). EASL Clinical Practice Guidelines: Management of hepatocellular carcinoma. Journal of Hepatology, 69(1), 182–236. https://doi.org/10.1016/j.jhep.2018.03.019
- Marrero, J. A., Kulik, L. M., Sirlin, C. B., Zhu, A. X., Finn, R. S., Abecassis, M. M., Roberts, L. R., & Heimbach, J. K. (2018). Diagnosis, Staging, and Management of Hepatocellular Carcinoma: 2018 Practice Guidance by the American Association for the Study of Liver Diseases. Hepatology, 68(2), 723–750. https://doi.org/10.1002/hep.29913
- Kim, S. Y., An, J., Lim, Y.-S., Han, S., Lee, J.-Y., Byun, J. H., Won, H. J., Lee, S. J., Lee, H. C., & Lee, Y. S. (2017). MRI With Liver-Specific Contrast for Surveillance of Patients With Cirrhosis at High Risk of Hepatocellular Carcinoma. JAMA Oncology, 3(4), 456. https://doi.org/10.1001/jamaoncol.2016.3147
- Gupta, P., Soundararajan, R., Patel, A., Kumar-M, P., Sharma, V., & Kalra, N. (2021). Abbreviated MRI for hepatocellular carcinoma screening: A systematic review and meta-analysis. Journal of Hepatology, 75(1), 108–119. https://doi.org/10.1016/j.jhep.2021.01.041
- Kim, D. H., Choi, S. H., Shim, J. H., Kim, S. Y., Lee, S. S., Byun, J. H., Kim, K. W., & Choi, J.-I. (2021). Magnetic Resonance Imaging for Surveillance of Hepatocellular Carcinoma: A Systematic Review and Meta-Analysis. Diagnostics, 11(9), 1665. https://doi.org/10.3390/diagnostics11091665
- Kim, D. H., Choi, S. H., Shim, J. H., Kim, S. Y., Lee, S. S., Byun, J. H., & Choi, J.-I. (2021). Meta-Analysis of the Accuracy of Abbreviated Magnetic Resonance Imaging for Hepatocellular Carcinoma Surveillance: Non-Contrast versus Hepatobiliary Phase-Abbreviated Magnetic Resonance Imaging. Cancers, 13(12), 2975. https://doi.org/10.3390/cancers13122975
- Whang, S., Choi, M. H., Choi, J.-I., Youn, S. Y., Kim, D. H., & Rha, S. E. (2020). Comparison of diagnostic performance of non-contrast MRI and abbreviated MRI using gadoxetic acid in initially diagnosed hepatocellular carcinoma patients: a simulation study of surveillance for hepatocellular carcinomas. European Radiology, 30(8), 4150–4163. https://doi.org/10.1007/s00330-020-06754-4
- Vietti Violi, N., Lewis, S., Liao, J., Hulkower, M., Hernandez-Meza, G., Smith, K., Babb, J. S., Chin, X., Song, J., Said, D., Kihira, S., Sirlin, C. B., Reeder, S. B., Bashir, M. R., Fowler, K. J., Ferket, B. S., Sigel, K., & Taouli, B. (2020). Gadoxetate-enhanced abbreviated MRI is highly accurate for hepatocellular carcinoma screening. European Radiology, 30(11), 6003–6013. https://doi.org/10.1007/s00330-020-07014-1
- Marks, R. M., Ryan, A., Heba, E. R., Tang, A., Wolfson, T. J., Gamst, A. C., Sirlin, C. B., & Bashir, M. R. (2015). Diagnostic Per-Patient Accuracy of an Abbreviated Hepatobiliary Phase Gadoxetic Acid–Enhanced MRI for Hepatocellular Carcinoma Surveillance. American Journal of Roentgenology, 204(3), 527–535. https://doi.org/10.2214/ajr.14.12986
1–25 of 91
Citations
- Fullerton, G. C., Tang, J., Starekova, J., Heidenreich, J. F., Pirasteh, A., Harris, D. T., Tamada, D., Buelo, C. J., Rettmann, D. W., Hernando, D., & Reeder, S. B. (2026). High‐Throughput Quantitative Chemical Shift‐Encoded MRI of the Liver. Journal of Magnetic Resonance Imaging, 64(5), 1398–1410. https://doi.org/10.1002/jmri.70429
- Fullerton, G. C., Starekova, J., Buelo, C. J., Harris, D. T., do Vale Souza, R., Faacks, A., Anagnostopoulos, A. A., Christofi, V. P., Murphy, A., Kadi, D., Yokoo, T., Bashir, M. R., Reeder, S. B., & Hernando, D. (2026). Multicenter, Multivendor Development and Validation of Automated Liver Prescription. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70575
- Breen, B., Alghofaily, K., Christensen, H. S., Frøkjær, J. B., Graumann, O., Kleivane, M., Medrud, L., Mikalone, R., Müller, S., Naujokaite, G., Negård, A., Salte, I. M., Schieda, N., & Borgbjerg, J. (2026). Agreement of axial T2-MRI versus Contrast-Enhanced CT for solid renal mass active surveillance. Abdominal Radiology, 51(10), 4779–4789. https://doi.org/10.1007/s00261-026-05376-6
- Lewis, S., Ahluwalia, A., Landis, D., Altinmakas, E., Kirsner, A., Yu, R., Doucette, J., Wong, S.-Y., Colombel, J.-F., & Taouli, B. (2026). Value of non-contrast magnetic resonance imaging for diagnosis of perianal fistulas in Crohn's disease. Journal of Crohn's and Colitis, 20(11). https://doi.org/10.1093/ecco-jcc/jjag183
- Tirukkovalur, N. V., Katabathina, V. A., Tammisetti, V. S., Jalluri, G. D., Ngan, K.-K., Borhani, A. A., & Dasyam, A. K. (2026). Navigating the Pancreatic Duct: Up-to-Date Radiologic Expedition through Intraluminal Pathologic Entities. RadioGraphics, 46(11). https://doi.org/10.1148/rg.250207
- Kim, S. Y., Won, S. E., Park, H. J., Woo, C., Kim, D. W., Suh, C. H., & Kim, K. W. (2026). Potential Role of Imaging in the Evaluation of Adiposity and Approval of Anti-Obesity Drugs. Korean Journal of Radiology, 27(1), 48. https://doi.org/10.3348/kjr.2025.0937
- Kulkarni, A. M., Kruse, D., Harper, K., Lam, E., Osman, H., Ansari, D. H., Sivanesan, U., Bashir, M. R., Costa, A. F., McInnes, M., & van der Pol, C. B. (2025). Current State of Evidence for Use of MRI in LI‐RADS. Journal of Magnetic Resonance Imaging, 62(3), 640–653. https://doi.org/10.1002/jmri.29748
- Hecht, E. M., Hu, H. H., Serai, S. D., Wu, H. H., Brunsing, R. L., Guimaraes, A. R., Kurugol, S., Ringe, K. I., Syed, A. B., & Group, . on . behalf . of . the I. B. M. S. (2025). Summary from the 2025 International Society for Magnetic Resonance in Medicine workshop on body MRI : Unsolved problems and unmet needs. Magnetic Resonance in Medicine, 95(1), 74–85. https://doi.org/10.1002/mrm.70055
- Zhong, J., Xing, Y., Hu, Y., Liu, X., Dai, S., Ding, D., Lu, J., Yang, J., Song, Y., Lu, M., Nickel, D., Lu, W., Zhang, H., & Yao, W. (2025). Assessment of Robustness of MRI Radiomic Features in the Abdomen: Impact of Deep Learning Reconstruction and Accelerated Acquisition. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-025-01503-9
- Min, J. H., Kim, Y. K., Jeong, W. K., & Taouli, B. (2025). Abbreviated MRI for Hepatocellular Carcinoma Screening: A Comprehensive Review. Current Hepatology Reports, 24(1). https://doi.org/10.1007/s11901-025-00689-4
- Herold, A., Tsai, L. L., Lo, W.-C., Tabari, A., Wichtmann, B. D., Sharp, A., Clifford, B., Lang, M., Hartman, S. P., Melski, L. M., Waqas, M., Weber, M., Pianykh, O., Huang, S. Y., Harisinghani, M. G., & Catalano, O. A. (2025). Impact of optimized and conventional facility designs on outpatient abdominal MRI workflow efficiency. Scientific Reports, 15(1). https://doi.org/10.1038/s41598-025-94799-0
- Yoon, J. H., Choi, J.-I., Yoo, J., Jeon, S. K., Kim, J. H., Bae, J. S., Kang, H.-J., Kim, H., Youn, S. Y., Kim, D. H., Yu, S. J., Kim, Y. J., Yoon, J.-H., Jang, J. W., Sung, P. S., Jang, M.-. jin ., & Lee, J. M. (2025). Comparison of Annual Dynamic Abbreviated MRI and Biannual Ultrasound for HCC Surveillance in a High-Risk Group: Two-Center Cohort Study. Liver Cancer, 1–14. https://doi.org/10.1159/000548516
- Sussman, M. S., Cui, L., Tan, S. B. M., Prasla, S., Wah-Kahn, T., Nickel, D., & Jhaveri, K. S. (2025). Deep Learning Reconstruction for T2 Weighted Turbo-Spin-Echo Imaging of the Pelvis: Prospective Comparison With Standard T2-Weighted TSE Imaging With Respect to Image Quality, Lesion Depiction, and Acquisition Time. Canadian Association of Radiologists Journal, 77(1), 119–127. https://doi.org/10.1177/08465371251357790
- Park, S. H., Choi, M. H., Kim, B., Lee, H.-S., Yoon, S., Lee, Y. J., Nickel, D., & Benkert, T. (2025). Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation. Korean Journal of Radiology, 26(4), 333. https://doi.org/10.3348/kjr.2024.0862
- Soler-Fernández, R., Méndez-Díaz, C., & Rodríguez-García, E. (2024). Medios de contraste basados en gadolinio de distribución extracelular. Radiología, 66, S51–S64. https://doi.org/10.1016/j.rx.2024.04.007
- Soler-Fernández, R., Méndez-Díaz, C., & Rodríguez-García, E. (2024). Extracellular gadolinium-based contrast agents. Radiología (English Edition), 66, S51–S64. https://doi.org/10.1016/j.rxeng.2024.04.004