Matrix layer sample preparation: An improved MALDI‐MS peptide analysis method for proteomic studies
Description
AbstractThe analytical performance of MALDI‐MS is highly influenced by sample preparation and the choice of matrix. Here we present an improved MALDI‐MS sample preparation method for peptide mass mapping and peptide analysis, based on the use of the 2,5‐dihydroxybenzoic acid matrix and prestructured sample supports, termed: matrix layer (ML). This sample preparation is easy to use and results in a rapid automated MALDI‐MS and MS/MS with high quality spectra acquisition. The between‐spot variation was investigated using standard peptides and statistical treatment of data confirmed the improvement gained with the ML method. Furthermore, the sample preparation method proved to be highly sensitive, in the lower‐attomole range for peptides, and we improved the performance of MALDI‐MS/MS for characterization of phosphopeptides as well. The method is versatile for the routine analysis of in‐gel tryptic digests thereby allowing for an improved protein sequence coverage. Furthermore, reliable protein identification can be achieved without the need of desalting sample preparation. We demonstrate the performance and the robustness of our method using commercially available reference proteins and automated MS and MS/MS analyses of in‐gel digests from lung tissue lysate proteins separated by 2‐DE.
Additional details
Identifiers
Dates
- Issued
-
July 2008
References
- Karas, M., & Hillenkamp, F. (1988). Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. Analytical Chemistry, 60(20), 2299–2301. https://doi.org/10.1021/ac00171a028
- Karas, M., Ingendoh, A., Bahr, U., & Hillenkamp, F. (1989). Ultraviolet-laser desorption/ionization mass spectrometry of femtomolar amounts of large proteins. Biological Mass Spectrometry, 18(9), 841–843. https://doi.org/10.1002/bms.1200180931
- Beavis, R. C., Chaudhary, T., & Chait, B. T. (1992). α‐Cyano‐4‐hydroxycinnamic acid as a matrix for matrixassisted laser desorption mass spectromtry. Organic Mass Spectrometry, 27(2), 156–158. https://doi.org/10.1002/oms.1210270217
- Strupat, K., Karas, M., & Hillenkamp, F. (1991). 2,5-Dihydroxybenzoic acid: a new matrix for laser desorption—ionization mass spectrometry. International Journal of Mass Spectrometry and Ion Processes, 111, 89–102. https://doi.org/10.1016/0168-1176(91)85050-v
- Cohen, S. L., & Chait, B. T. (1996). Influence of Matrix Solution Conditions on the MALDI-MS Analysis of Peptides and Proteins. Analytical Chemistry, 68(1), 31–37. https://doi.org/10.1021/ac9507956
- Önnerfjord, P., Ekström, S., Bergquist, J., Nilsson, J., Laurell, T., & Marko-Varga, G. (1999). Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. Rapid Communications in Mass Spectrometry, 13(5), 315–322. https://doi.org/10.1002/(sici)1097-0231(19990315)13:5%3C315::aid-rcm483%3E3.0.co;2-c
- Andalò, C., Bocchini, P., Pozzi, R., & Galletti, G. C. (2001). Accurate mass measurement of synthetic analogues of prazosine by matrix‐assisted laser desorption/ionisation time‐of‐flight mass spectrometry. Rapid Communications in Mass Spectrometry, 15(9), 665–669. https://doi.org/10.1002/rcm.272
- Cohen, L. H., & Gusev, A. I. (2002). Small molecule analysis by MALDI mass spectrometry. Analytical and Bioanalytical Chemistry, 373(7), 571–586. https://doi.org/10.1007/s00216-002-1321-z
- Nicola, A. J., Gusev, A. I., Proctor, A., Jackson, E. K., & Hercules, D. M. (1995). Application of the fast‐evaporation sample preparation method for improving quantification of angiotensin II by matrix‐assisted laser desorption/ionization. Rapid Communications in Mass Spectrometry, 9(12), 1164–1171. https://doi.org/10.1002/rcm.1290091216
- Stoeckli, M., Farmer, T. B., & Caprioli, R. M. (1999). Automated mass spectrometry imaging with a matrix-assisted laser desorption ionization time-of-flight instrument. Journal of the American Society for Mass Spectrometry, 10(1), 67–71. https://doi.org/10.1016/s1044-0305(98)00126-3
- Anderson, N. L., & Anderson, N. G. (2002). The Human Plasma Proteome. Molecular & Cellular Proteomics, 1(11), 845–867. https://doi.org/10.1074/mcp.r200007-mcp200
- Lisacek, F. C., Traini, M. D., Sexton, D., Harry, J. L., & Wilkins, M. R. (2001). Strategy for protein isoform identification from expressed sequence tags and its application to peptide mass fingerprinting. PROTEOMICS, 1(2), 186–193. https://doi.org/10.1002/1615-9861(200102)1:2%3C186::aid-prot186%3E3.0.co;2-g
- Claverol, S., Burlet-Schiltz, O., Girbal-Neuhauser, E., Gairin, J. E., & Monsarrat, B. (2002). Mapping and Structural Dissection of Human 20 S Proteasome Using Proteomic Approaches. Molecular & Cellular Proteomics, 1(8), 567–578. https://doi.org/10.1074/mcp.m200030-mcp200
- Shevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M. (1996). Linking genome and proteome by mass spectrometry: Large-scale identification of yeast proteins from two dimensional gels. Proceedings of the National Academy of Sciences, 93(25), 14440–14445. https://doi.org/10.1073/pnas.93.25.14440
- Juhasz, P., Costello, C. E., & Biemann, K. (1993). Matrix-assisted laser desorption ionization mass spectrometry with 2-(4-hydroxyphenylazo)benzoic acid matrix. Journal of the American Society for Mass Spectrometry, 4(5), 399–409. https://doi.org/10.1016/1044-0305(93)85005-i
- Vorm, O., Roepstorff, P., & Mann, M. (1994). Improved Resolution and Very High Sensitivity in MALDI TOF of Matrix Surfaces Made by Fast Evaporation. Analytical Chemistry, 66(19), 3281–3287. https://doi.org/10.1021/ac00091a044
- Kussmann, M., Nordhoff, E., Rahbek-Nielsen, H., Haebel, S., Rossel-Larsen, M., Jakobsen, L., Gobom, J., Mirgorodskaya, E., Kroll-Kristensen, A., Palm‖, L., & Roepstorff, P. (1997). Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Sample Preparation Techniques Designed for Various Peptide and Protein Analytes. Journal of Mass Spectrometry, 32(6), 593–601. https://doi.org/10.1002/(sici)1096-9888(199706)32:6%3C593::aid-jms511%3E3.0.co;2-d
- Dai, Y., Whittal, R. M., & Li, L. (1996). Confocal Fluorescence Microscopic Imaging for Investigating the Analyte Distribution in MALDI Matrices. Analytical Chemistry, 68(15), 2494–2500. https://doi.org/10.1021/ac960238z
- Kjellström, S., & Jensen, O. N. (2004). Phosphoric Acid as a Matrix Additive for MALDI MS Analysis of Phosphopeptides and Phosphoproteins. Analytical Chemistry, 76(17), 5109–5117. https://doi.org/10.1021/ac0400257
- Garden, R. W., & Sweedler, J. V. (1999). Heterogeneity within MALDI Samples As Revealed by Mass Spectrometric Imaging. Analytical Chemistry, 72(1), 30–36. https://doi.org/10.1021/ac9908997
- Schuerenberg, M., Luebbert, C., Eickhoff, H., Kalkum, M., Lehrach, H., & Nordhoff, E. (2000). Prestructured MALDI-MS Sample Supports. Analytical Chemistry, 72(15), 3436–3442. https://doi.org/10.1021/ac000092a
- Johnson, T., Bergquist, J., Ekman, R., Nordhoff, E., Schürenberg, M., Klöppel, K.-D., Müller, M., Lehrach, H., & Gobom, J. (2001). A CE−MALDI Interface Based on the Use of Prestructured Sample Supports. Analytical Chemistry, 73(8), 1670–1675. https://doi.org/10.1021/ac0011888
- Doherty, N. S., Littman, B. H., Reilly, K., Swindell, A. C., Buss, J. M., & Anderson, N. L. (1998). Analysis of changes in acute‐phase plasma proteins in an acute inflammatory response and in rheumatoid arthritis using two‐dimensional gel electrophoresis. ELECTROPHORESIS, 19(2), 355–363. https://doi.org/10.1002/elps.1150190234
- Ferrari, G., Garaguso, I., Adu‐Bobie, J., Doro, F., Taddei, A. R., Biolchi, A., Brunelli, B., Giuliani, M. M., Pizza, M., Norais, N., & Grandi, G. (2006). Outer membrane vesicles from group B Neisseria meningitidis Δgna33 mutant: Proteomic and immunological comparison with detergent‐derived outer membrane vesicles. PROTEOMICS, 6(6), 1856–1866. https://doi.org/10.1002/pmic.200500164
- Peptide sequencing of 2‐DE gel‐isolated proteins by nanoelectrospray tandem mass spectrometry
1–25 of 36
Citations
- Gegel, S., Kumar, A., Goudeva, L., & Borlak, J. (2026). Clinical plausibility of eggshell membrane proteins for osteoarthritis: a study of solubility, digestibility, and immune response. Molecular and Cellular Biochemistry, 481(8), 3497–3507. https://doi.org/10.1007/s11010-026-05608-9
- Kernalléguen, A., Kintz, P., Leonetti, G., Lafitte, D., & Pélissier-Alicot, A.-L. (2023). Recent Trends in MALDI-MS Drugs Analysis in Human Hair: Pre-Analytical and Analytical Challenges and Pitfalls. Journal of Analytical Toxicology, 47(5), 417–428. https://doi.org/10.1093/jat/bkad015
- Hasan, N., & Tasneem, S. (2021, December 16). Miniaturized Liquid Extractions in MALDI–MS Analysis. In Miniaturized Analytical Devices (1st ed., pp. 219–260). Wiley. https://doi.org/10.1002/9783527827213.ch11
- Greco, V., Piras, C., Pieroni, L., Ronci, M., Putignani, L., Roncada, P., & Urbani, A. (2018). Applications of MALDI-TOF mass spectrometry in clinical proteomics. Expert Review of Proteomics, 15(8), 683–696. https://doi.org/10.1080/14789450.2018.1505510
- Towers, M. W., & Cramer, R. (2016). Ionic Liquids and Other Liquid Matrices for Sensitive MALDI MS Analysis. In Advances in MALDI and Laser-Induced Soft Ionization Mass Spectrometry (pp. 51–64). Springer International Publishing. https://doi.org/10.1007/978-3-319-04819-2_3
- Biomarker Characterization by MALDI–TOF/MS. (2015). Biomarker Characterization by MALDI–TOF/MS. In Advances in Clinical Chemistry (pp. 209–254). Elsevier. https://doi.org/10.1016/bs.acc.2015.01.001
- Park, E. J., Han, S. W., Jeong, B., Park, S. H., Kim, Y.-G., Kim, Y. H., & Kim, Y. D. (2015). Effect of polydimethylsiloxane (PDMS) coating on TiO2-based MALDI matrix for dimethyl methylphosphonate (DMMP) analysis. Applied Surface Science, 353, 342–349. https://doi.org/10.1016/j.apsusc.2015.06.122
- https://doi.org/10.1371/journal.pone.0124867
- Ruh, H., Sandhoff, R., Meyer, B., Gretz, N., & Hopf, C. (2013). Quantitative Characterization of Tissue Globotetraosylceramides in a Rat Model of Polycystic Kidney Disease by PrimaDrop Sample Preparation and Indirect High-Performance Thin Layer Chromatography–Matrix-Assisted Laser Desorption/Ionization-Time-of-Flight-Mass Spectrometry with Automated Data Acquisition. Analytical Chemistry, 85(13), 6233–6240. https://doi.org/10.1021/ac400931u
- https://doi.org/10.1371/journal.pone.0050025
- da Silva, D., Wasselin, T., Carré, V., Chaimbault, P., Bezdetnaya, L., Maunit, B., & Muller, J. (2011). Evaluation of combined matrix‐assisted laser desorption/ionization time‐of‐flight and matrix‐assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry experiments for peptide mass fingerprinting analysis. Rapid Communications in Mass Spectrometry, 25(13), 1881–1892. https://doi.org/10.1002/rcm.5057
- Assumpção, T. C. F., Charneau, S., Santiago, P. B. M., Francischetti, I. M. B., Meng, Z., Araújo, C. N., Pham, V. M., Queiroz, R. M. L., Nery de Castro, C., André Ricart, C., Santana, J. M., & Ribeiro, J. M. C. (2011). Insight into the Salivary Transcriptome and Proteome of Dipetalogaster maxima. Journal of Proteome Research, 10(2), 669–679. https://doi.org/10.1021/pr100866h
- Lee, J., Hwang, Y. J., Boo, J. H., Han, D., Kwon, O. K., Todorova, K., Kowall, N. W., Kim, Y., & Ryu, H. (2011). Dysregulation of upstream binding factor-1 acetylation at K352 is linked to impaired ribosomal DNA transcription in Huntington's disease. Cell Death & Differentiation, 18(11), 1726–1735. https://doi.org/10.1038/cdd.2011.38
- Condina, M. R., Klingler‐Hoffmann, M., & Hoffmann, P. (2010). Tyrosine Phosphorylation Enrichment and Subsequent Analysis by MALDI‐TOF/TOF MS/MS and LC‐ESI‐IT‐MS/MS. Current Protocols in Protein Science, 62(1). https://doi.org/10.1002/0471140864.ps1311s62
- Condina, M. R., Gustafsson, J. O. R., Klingler‐Hoffmann, M., Bagley, C. J., McColl, S. R., & Hoffmann, P. (2010). EZYprep LC‐coupled MALDI‐TOF/TOF MS: An improved matrix spray application for phosphopeptide characterisation. PROTEOMICS, 10(13), 2516–2530. https://doi.org/10.1002/pmic.200900800
- Umemura, H., Kodera, Y., & Nomura, F. (2010). Effects of humidity on the dried-droplet sample preparation for MALDI–TOF MS peptide profiling. Clinica Chimica Acta, 411(23-24), 2109–2111. https://doi.org/10.1016/j.cca.2010.08.010
- Rodthongkum, N., Chen, Y., Thayumanavan, S., & Vachet, R. W. (2010). Matrix-Assisted Laser Desorption Ionization-Mass Spectrometry Signal Enhancement of Peptides after Selective Extraction with Polymeric Reverse Micelles. Analytical Chemistry, 82(9), 3686–3691. https://doi.org/10.1021/ac1000256
- Garaguso, I., Halter, R., Krzeminski, J., Amin, S., & Borlak, J. (2010). Method for the Rapid Detection and Molecular Characterization of DNA Alkylating Agents by MALDI-TOF Mass Spectrometry. Analytical Chemistry, 82(20), 8573–8582. https://doi.org/10.1021/ac101568h
- Current literature in mass spectrometry. (2009). Current literature in mass spectrometry. Journal of Mass Spectrometry, 44(2), 288–299. https://doi.org/10.1002/jms.1487
- Xingwei, W., Haifeng, L., Mei, X., Gang, C., Juntang, H., Guo'an, W., Xiaochun, T., & Dianchun, F. (2009). Proteomic analysis of down-regulated proteins in colonic mucosa of chronic slow transit constipation rats. Journal of Medical Colleges of PLA, 24(3), 136–141. https://doi.org/10.1016/s1000-1948(09)60029-0
- Abu-Farha, M., Elisma, F., Zhou, H., Tian, R., Zhou, H., Asmer, M. S., & Figeys, D. (2009). Proteomics: From Technology Developments to Biological Applications. Analytical Chemistry, 81(12), 4585–4599. https://doi.org/10.1021/ac900735j
- Shrivas, K., & Wu, H. (2008). Functionalized‐multiwalled carbon nanotubes as a preconcentrating probe for rapid monitoring of cationic dyestuffs in environmental water using AP‐MALDI/MS. Journal of Separation Science, 31(20), 3603–3611. https://doi.org/10.1002/jssc.200800318
- https://doi.org/10.1586/14789450.5.6.841