Predicting prosthetic gait and the effects of induced stiff-knee gait
Authors/Creators
Contributors
Editor:
Description
Prosthetic gait differs considerably from the unimpaired gait. Studying alterations in the gait patterns could help to understand different adaptation mechanisms adopted by these populations. This study investigated the effects of induced stiff-knee gait (SKG) on prosthetic and healthy gait patterns and the capabilities of predictive simulation. Self-selected speed gait of two participants was measured: one healthy subject and one knee disarticulation subject using a variable-damping microprocessor controlled knee prosthesis. Both performed unperturbed gait and gait with restricted knee flexion. Experimental joint angles and moments were computed using OpenSim and muscle activity was measured using surface electromyography (EMG). The differences between the conditions were analyzed using statistical parametric mapping (SPM). Predictive models based on optimal control were created to represent the participants. Additionally, a hypothetical unimpaired predictive model with the same anthropometric characteristics as the amputee was created. Some patterns observed in the experimental prosthetic gait were predicted by the models, including increased knee flexion moment on the contralateral side caused by SKG in both participants, which was statistically significant according to SPM. With the exception of the rectus femoris muscle, we also found overall good agreement between measured EMG and predicted muscle activation. We predicted more alterations in activation of the hip flexors than other muscle groups due to the amputation and in the activation of the biceps femoris short head, quadratus femoris, and tibialis anterior due to SKG. In summary, we demonstrated that the method applied in this study could predict gait alterations due to amputation of the lower limb or due to imposed SKG.
Additional details
Identifiers
- OpenAlex
- W4406015094
- PMID
- 39746053
- URL
- https://dx.plos.org/10.1371/journal.pone.0314758
Funding
-
Deutsche Forschungsgemeinschaft
- 316739714
Dates
- Issued
-
January 2, 2025
References
- Hammarlund, C. S., Carlström, M., Melchior, R., & Persson, B. M. (2011). Prevalence of back pain, its effect on functional ability and health-related quality of life in lower limb amputees secondary to trauma or tumour. Prosthetics & Orthotics International, 35(1), 97–105. https://doi.org/10.1177/0309364610389357
- Moxey, P. W., Gogalniceanu, P., Hinchliffe, R. J., Loftus, I. M., Jones, K. J., Thompson, M. M., & Holt, P. J. (2011). Lower extremity amputations - a review of global variability in incidence. Diabetic Medicine, 28(10), 1144–1153. https://doi.org/10.1111/j.1464-5491.2011.03279.x
- Sawers, A. B., & Hafner, B. J. (2013). Outcomes associated with the use of microprocessor-controlled prosthetic knees among individuals with unilateral transfemoral limb loss: A systematic review. The Journal of Rehabilitation Research and Development, 50(3), 273. https://doi.org/10.1682/jrrd.2011.10.0187
- Kaufman, K. R., Frittoli, S., & Frigo, C. A. (2012). Gait asymmetry of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees. Clinical Biomechanics, 27(5), 460–465. https://doi.org/10.1016/j.clinbiomech.2011.11.011
- Bellmann, M., Schmalz, T., & Blumentritt, S. (2010). Comparative Biomechanical Analysis of Current Microprocessor-Controlled Prosthetic Knee Joints. Archives of Physical Medicine and Rehabilitation, 91(4), 644–652. https://doi.org/10.1016/j.apmr.2009.12.014
- Designs and performance of three new microprocessor-controlled knee joints.
- Johansson, J. L., Sherrill, D. M., Riley, P. O., Bonato, P., & Herr, H. (2005). A Clinical Comparison of Variable-Damping and Mechanically Passive Prosthetic Knee Devices. American Journal of Physical Medicine & Rehabilitation, 84(8), 563–575. https://doi.org/10.1097/01.phm.0000174665.74933.0b
- Herr, H., & Wilkenfeld, A. (2003). User‐adaptive control of a magnetorheological prosthetic knee. Industrial Robot: An International Journal, 30(1), 42–55. https://doi.org/10.1108/01439910310457706
- Ackermann, M., & van den Bogert, A. J. (2010). Optimality principles for model-based prediction of human gait. Journal of Biomechanics, 43(6), 1055–1060. https://doi.org/10.1016/j.jbiomech.2009.12.012
- Falisse, A., Serrancolí, G., Dembia, C. L., Gillis, J., Jonkers, I., & De Groote, F. (2019). Rapid predictive simulations with complex musculoskeletal models suggest that diverse healthy and pathological human gaits can emerge from similar control strategies. Journal of The Royal Society Interface, 16(157), 20190402. https://doi.org/10.1098/rsif.2019.0402
- Koelewijn, A. D., & van den Bogert, A. J. (2016). Joint contact forces can be reduced by improving joint moment symmetry in below-knee amputee gait simulations. Gait & Posture, 49, 219–225. https://doi.org/10.1016/j.gaitpost.2016.07.007
- Price, M. A., Umberger, B. R., & Sup, F. C. (2019). Dynamic optimization of Gait with a Generalized Lower-Limb Prosthesis Model. 2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR), 734–739. https://doi.org/10.1109/icorr.2019.8779532
- Miller, R. H., Bell, E. M., & Russell Esposito, E. (2024). Transfemoral limb loss modestly increases the metabolic cost of optimal control simulations of walking. PeerJ, 12, e16756. https://doi.org/10.7717/peerj.16756
- Vandenberg, N. W., Wheatley, B. B., Carpenter, R. D., Christiansen, C. L., Stoneback, J. W., & Gaffney, B. M. M. (2024). Feasibility of predicting changes in gait biomechanics following muscle strength perturbations using optimal control in patients with transfemoral amputation. Computer Methods in Biomechanics and Biomedical Engineering, 29(2), 298–312. https://doi.org/10.1080/10255842.2024.2399038
- De Groote, F., & Falisse, A. (2021). Perspective on musculoskeletal modelling and predictive simulations of human movement to assess the neuromechanics of gait. Proceedings of the Royal Society B: Biological Sciences, 288(1946), 20202432. https://doi.org/10.1098/rspb.2020.2432
- Fregly, B. J. (2021). A Conceptual Blueprint for Making Neuromusculoskeletal Models Clinically Useful. Applied Sciences, 11(5), 2037. https://doi.org/10.3390/app11052037
- Santos, G. F., Jakubowitz, E., Pronost, N., Bonis, T., & Hurschler, C. (2021). Predictive simulation of post-stroke gait with functional electrical stimulation. Scientific Reports, 11(1). https://doi.org/10.1038/s41598-021-00658-z
- Tok, F., Balaban, B., Yaşar, E., Alaca, R., & Tan, A. K. (2012). The Effects of Onabotulinum Toxin A Injection into Rectus Femoris Muscle in Hemiplegic Stroke Patients with Stiff-Knee Gait. American Journal of Physical Medicine & Rehabilitation, 91(4), 321–326. https://doi.org/10.1097/phm.0b013e3182465feb
- Campanini, I., Merlo, A., & Damiano, B. (2013). A method to differentiate the causes of stiff-knee gait in stroke patients. Gait & Posture, 38(2), 165–169. https://doi.org/10.1016/j.gaitpost.2013.05.003
- Celestino, M. L., van Emmerik, R., Barela, J. A., Bacca, O., & Barela, A. M. F. (2021). Effects of limited knee flexion movement in intra-limb gait coordination. Journal of Biomechanics, 128, 110712. https://doi.org/10.1016/j.jbiomech.2021.110712
- Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990). Measurement of lower extremity kinematics during level walking. Journal of Orthopaedic Research, 8(3), 383–392. https://doi.org/10.1002/jor.1100080310
- Einfeldt, A.-K., Yao, D., Daniilidis, K., Calliess, T., Welke, B., & Jakubowitz, E. (2022). Knee disarticulation following oncologic total knee arthroplasty: A 5-year follow-up case report. Clinical Biomechanics, 94, Article 105608. https://doi.org/10.1016/j.clinbiomech.2022.105608
- Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007). OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement. IEEE Transactions on Biomedical Engineering, 54(11), 1940–1950. https://doi.org/10.1109/tbme.2007.901024
- Approach for gait analysis in persons with limb loss including residuum and prosthesis socket dynamics. Int J Numer Meth Biomed Engng
- Falisse, A., Pitto, L., Kainz, H., Hoang, H., Wesseling, M., Van Rossom, S., Papageorgiou, E., Bar-On, L., Hallemans, A., Desloovere, K., Molenaers, G., Van Campenhout, A., De Groote, F., & Jonkers, I. (2020). Physics-Based Simulations to Predict the Differential Effects of Motor Control and Musculoskeletal Deficits on Gait Dysfunction in Cerebral Palsy: A Retrospective Case Study. Frontiers in Human Neuroscience, 14. https://doi.org/10.3389/fnhum.2020.00040
1–25 of 49
Citations
- Borkowski, R., & Błażkiewicz, M. (2026). Muscle force responses during initial-contact gait perturbations and recovery steps. Gait & Posture, 130, 110602. https://doi.org/10.1016/j.gaitpost.2026.110602
- Berettoni, A., De Giuseppe, S., Mariani, G., Boccardo, N., Laffranchi, M., & Semprini, M. (2025). Exploration of biomechanics, mental workload and metabolism factors during prosthetic gait. Progress in Biomedical Engineering, 7(4), 043002. https://doi.org/10.1088/2516-1091/ae0f11