Published February 1996 | Journal article | Version v1 | https://doi.org/10.1111/j.1365-2044.1996.tb07703.x

Evaluation of two electrochemical monitors for measurement of inhaled nitric oxide

Description

Summary Inhaled in low concentrations, nitric oxide (NO) acts as a potent pulmonary vasodilator, but when inhaled in high concentrations NO and its metabolite NO 2 are potentially toxic molecules. Thus, an accurate and reproducible measurement of both NO and NO 2 is necessary, and changes in NO concentration need to be detected instantly to avoid lung damage (high concentrations) or failure of NO therapy (low concentrations; unnoticed interruption of NO supply). We investigated two electrochemical NO monitors (Sensor Stik 4586 and Dräger PAC II)for accuracy and time constants. Both provided accurate and reproducible results at different NO concentrations. Known NO concentrations (standards: 10, 50, 75ppm) were detected within a 3% tolerance, and acceptable time constants were seen when NO concentration was abruptly increased from zero to 50 ppm. The display read the final value within 60s with the Sensor Stik and lls with the Dräger PAC II. Significant differences were seen when the NO concentration was rapidly reduced from 50 ppm to zero. The Sensor Stik took more than 2 h to reach zero, whereas the PAC II took 60s.

Additional details

Dates

Issued
February 1996

References

  1. Frostell, C., Fratacci, M. D., Wain, J. C., Jones, R., & Zapol, W. M. (1991). Inhaled nitric oxide. A selective pulmonary vasodilator reversing hypoxic pulmonary vasoconstriction. Circulation, 83(6), 2038–2047. https://doi.org/10.1161/01.cir.83.6.2038
  2. Rich, G. F., Murphy, G. D., Roos, C. M., & Johns, R. A. (1993). Inhaled Nitric Oxide. Anesthesiology, 78(6), 1028–1035. https://doi.org/10.1097/00000542-199306000-00004
  3. Rossaint, R., Falke, K. J., Lopez, F., Slama, K., Pison, U., & Zapol, W. M. (1993). Inhaled Nitric Oxide for the Adult Respiratory Distress Syndrome. New England Journal of Medicine, 328(6), 399–405. https://doi.org/10.1056/nejm199302113280605
  4. Inhalation of nitric oxide—a new approach in severe ARDS
  5. Gerlach, H., Pappert, D., Lewandowski, K., Rossaint, R., & Falke, K. J. (1993). Long-term inhalation with evaluated low doses of nitric oxide for selective improvement of oxygenation in patients with adult respiratory distress syndrome. Intensive Care Medicine, 19(8), 443–449. https://doi.org/10.1007/bf01711084
  6. KINSELLA, J. (1992). Low-dose inhalational nitric oxide in persistent pulmonary hypertension of the newborn. The Lancet, 340(8823), 819–820. https://doi.org/10.1016/0140-6736(92)92687-b
  7. ROBERTS, J. (1992). Inhaled nitric oxide in persistent pulmonary hypertension of the newborn. The Lancet, 340(8823), 818–819. https://doi.org/10.1016/0140-6736(92)92686-a
  8. KINSELLA, J. P., & ABMAN, S. H. (1993). Inhalational Nitric Oxide Therapy for Persistent Pulmonary Hypertension of the Newborn. Pediatrics, 91(5), 997–998. https://doi.org/10.1542/peds.91.5.997
  9. Kinsella, J. P., & Abman, S. H. (1994). Efficacy of Inhalational Nitric Oxide Therapy in the Clinical Management of Persistent Pulmonary Hypertension of the Newborn. Chest, 105(3), 92S–94S. https://doi.org/10.1378/chest.105.3_supplement.92s
  10. Roberts, J. D., Lang, P., Bigatello, L. M., Vlahakes, G. J., & Zapol, W. M. (1993). Inhaled nitric oxide in congenital heart disease. Circulation, 87(2), 447–453. https://doi.org/10.1161/01.cir.87.2.447
  11. Winberg, P., Lundell, B. P., & Gustafsson, L. E. (1994). Effect of inhaled nitric oxide on raised pulmonary vascular resistance in children with congenital heart disease. Heart, 71(3), 282–286. https://doi.org/10.1136/hrt.71.3.282
  12. Girard, C., Lehot, J.-J., Pannetier, J.-C., Filley, S., Ffrench, P., & Estanove, S. (1992). Inhaled Nitric Oxide after Mitral Valve Replacement in Patients with Chronic Pulmonary Artery Hypertension. Anesthesiology, 77(5), 880–883. https://doi.org/10.1097/00000542-199211000-00007
  13. Journois, D., Pouard, P., Mauriat, P., Malhere, T., Vouhe, P., & Safran, D. (1994). Inhaled nitric oxide as a therapy for pulmonary hypertension after operations for congenital heart defects. The Journal of Thoracic and Cardiovascular Surgery, 107(4), 1129–1135. https://doi.org/10.1016/s0022-5223(94)70390-6
  14. Mercier, J.-C., Zupan, V., Dehan, M., Renaudin, M.-H., Bouchet, M., & Raveau, C. (1993). Device to monitor concentration of inhaled nitric oxide. The Lancet, 342(8868), 431–432. https://doi.org/10.1016/0140-6736(93)92843-i
  15. Inhaliertes Stickstoffmonoxid. Anwendung und kontinuierliche Konzentrationsmessung
  16. Petros, A. J., Cox, P. B., & Bohn, D. (1992). Simple method for monitoring concentration of inhaled nitric oxide. The Lancet, 340(8828), 1167. https://doi.org/10.1016/0140-6736(92)93201-w
  17. PETROS, A. J., COX, P., & BOHN, D. (1994). A simple method for monitoring the concentration of inhaled nitric oxide. Anaesthesia, 49(4), 317–319. https://doi.org/10.1111/j.1365-2044.1994.tb14183.x